2019-06-25 14:20:41 | ELECTRICAL PLAN REVIEW |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| BUILDING PLANS EXAMINER, PX3169 |
| 1&2 FAMILY PLANS EXAMINER, SFP306 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| BELOW. |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. PROVIDE PANEL SCHEDULE. INCLUDE ANY NEW CIRCUTS. |
| PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED |
| CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, |
| AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY |
| WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, |
| 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902. |
| |
| 2. PANEL SHALL BE LABELED. |
| E3401.4 ADDITIONS AND ALTERATIONS. |
| ANY ADDITION OR ALTERATION TO AN EXISTING ELECTRICAL |
| SYSTEM SHALL BE MADE IN CONFORMITY TO THE PROVISIONS OF |
| CHAPTERS 34 THROUGH 43. |
| |
| 3. OUTLET SPACING SHALL COMPLY WITH E3901.2.1. |
| RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT |
| MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL |
| SPACE IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET. |
| PROVIDE CORRECTION. NEC 210.52; FBC RE E3901.2.1. |
| |
| 4. PLAN INDICATES MAIN BREAKER PANEL IS 125 AMPS. |
| PUBLIC RECORDS INDICATE EXISTING PANEL TO BE 150 AMPS. |
| PLEASE CLARIFY. |
| |
| 5. LOAD CALCULATION PAGE REQUIRES ORIGINAL SIGNATURE OF |
| CONTRACTOR. |
| FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS |
| AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE |
| OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO |
| SECTION 107.3.5) AND F.S. 481.229. |
| |
| 6. SMOKE ALARMS SHALL COMPLY WITH R314. |
| |
| R314.2.2 ALTERATIONS, REPAIRS AND ADDITIONS. |
| |
| WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A |
| PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE |
| ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL |
| DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS |
| LOCATED AS REQUIRED FOR NEW DWELLINGS. |
| EXCEPTIONS: |
| 1.WORK INVOLVING THE EXTERIOR SURFACES OF DWELLINGS, |
| SUCH AS THE REPLACEMENT OF ROOFING OR SIDING, THE |
| ADDITION OR REPLACEMENT OF WINDOWS OR DOORS, OR THE |
| ADDITION OF A PORCH OR DECK, ARE EXEMPT FROM THE |
| REQUIREMENTS OF THIS SECTION. |
| 2.INSTALLATION, ALTERATION OR REPAIRS OF PLUMBING OR |
| MECHANICAL SYSTEMS ARE EXEMPT FROM THE REQUIREMENTS OF |
| THIS SECTION. |
| |
| R314.4 INTERCONNECTION. |
| WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE |
| INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT IN |
| ACCORDANCE WITH SECTION R314.3, THE ALARM DEVICES SHALL |
| BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION |
| OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE |
| INDIVIDUAL DWELLING UNIT. PHYSICAL INTERCONNECTION OF |
| SMOKE ALARMS SHALL NOT BE REQUIRED WHERE LISTED |
| WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND UPON |
| ACTIVATION OF ONE ALARM. |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| REVIEWED SHEETS DETACHED. |
| |
| |
| |