2019-06-14 14:36:58BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19051459
 REVIEWED: JUNE 14, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[R] = FBC RESIDENTIAL
  
 4501.17.1.8 FBC[R] ACCESS GATES, WHEN PROVIDED, SHALL
 BE SELF-CLOSING AND SHALL COMPLY WITH THE REQUIREMENTS
 OF SECTIONS R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL
 BE EQUIPPED WITH A SELF-LATCHING LOCKING DEVICE LOCATED
 ON THE POOL SIDE OF THE GATE. WHERE THE DEVICE RELEASE
 IS LOCATED NO LESS THAN 54 INCHES (1372 MM) FROM THE
 BOTTOM OF THE GATE, THE DEVICE RELEASE MECHANISM MAY BE
 LOCATED ON EITHER SIDE OF THE GATE AND SO PLACED THAT
 IT CANNOT BE REACHED BY A YOUNG CHILD OVER THE TOP OR
 THROUGH ANY OPENING OR GAP FROM THE OUTSIDE. GATES THAT
 PROVIDE ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD
 AWAY FROM THE POOL. THE GATES AND BARRIER SHALL HAVE NO
 OPENING GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18
 INCHES (457 MM) OF THE RELEASE MECHANISM.
 -PERMIT DESCRIPTION STATES SELF CLOSING AND LATCHING.
 THIS SHOULD BE ADDED AS A NOTE ON THE PLANS AND THE
 MINIMUM HEIGHT OF LATCH SHOULD BE INCLUDED. (SEE
 SECTION ABOVE THAT REQUIRES DEVICE RELEASE 54 INCHES
 MINIMUM FROM THE BOTTOM OF THE GATE)
  
 4501.17.1.9 FBC[R] WHERE A WALL OF A DWELLING SERVES AS
 PART OF THE BARRIER, ONE OF THE FOLLOWING SHALL APPLY:
 1. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM
 THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT
 ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND
 PRESSURE RATING OF 85 DBA AT 10 FEET (3048 MM). ANY
 DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES
 (1372 MM) ABOVE THE THRESHOLD OF THE ACCESS. SEPARATE
 ALARMS ARE NOT REQUIRED FOR EACH DOOR OR WINDOW IF
 SENSORS WIRED TO A CENTRAL ALARM SOUND WHEN CONTACT IS
 BROKEN AT ANY OPENING. EXCEPTIONS:
 A. SCREENED OR PROTECTED WINDOWS HAVING A BOTTOM SILL
 HEIGHT OF 48 INCHES (1219 MM) OR MORE MEASURED FROM THE
 INTERIOR FINISHED FLOOR AT THE POOL ACCESS LEVEL.
 B. WINDOWS FACING THE POOL ON FLOOR ABOVE THE FIRST
 STORY.
 C. SCREENED OR PROTECTED PASS-THROUGH KITCHEN WINDOWS
 42 INCHES (1067 MM) OR HIGHER WITH A COUNTER BENEATH.
 2. ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO
 THE POOL MUST BE EQUIPPED WITH A SELF-CLOSING,
 SELF-LATCHING DEVICE WITH POSITIVE MECHANICAL
 LATCHING/LOCKING INSTALLED A MINIMUM OF 54 INCHES (1372
 MM) ABOVE THE THRESHOLD, WHICH IS APPROVED BY THE
 AUTHORITY HAVING JURISDICTION.
 3. A SWIMMING POOL ALARM THAT, WHEN PLACED IN A POOL,
 SOUNDS AN ALARM UPON DETECTION OF AN ACCIDENTAL OR
 UNAUTHORIZED ENTRANCE INTO THE WATER. SUCH POOL ALARM
 MUST MEET AND BE INDEPENDENTLY CERTIFIED TO ASTM
 STANDARD F2208, TITLED ?STANDARD SAFETY SPECIFICATION
 FOR RESIDENTIAL POOL ALARMS,? WHICH INCLUDES SURFACE
 MOTION, PRESSURE, SONAR, LASER, AND INFRARED ALARMS.
 FOR PURPOSES OF THIS PARAGRAPH, THE TERM ?SWIMMING POOL
 ALARM? DOES NOT INCLUDE ANY SWIMMING PROTECTION ALARM
 DEVICE DESIGNED FOR INDIVIDUAL USE, SUCH AS AN ALARM
 ATTACHED TO A CHILD THAT SOUNDS WHEN THE CHILD EXCEEDS
 A CERTAIN DISTANCE OR BECOMES SUBMERGED IN WATER.
  -HOW ARE THE ACCESS POINTS FROM THE REAR OF HOME TO
 POOL PROTECTED AS REQUIRED PER 4501.17.1.9.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  