Plan Review Notes For Permit 19051206 |
Permit Number |
19051206 |
|
Review Stop |
G |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2019-05-28 13:43:55 | 1) THE RECORD GAS DRAWINGS ON FILE IN THE CITY SHOW THE | | FOLLOWING BTU VALUES FOR THE LISTED APPLIANCES: | | POOL HEATER - 400,000 BTU'S | | DRYER - 40,000 BTU'S | | FIRELOGS - 44,000 | | GENERATOR - 560,000 BTU'S | | RANGE - 300,000 BTU'S | | WATER HEATER - 75,000 | | TOTAL BTU LOAD - 1,419,000 BTU'S | | | | THE GAS DRAWING SUBMITTED FOR THIS PERMIT SHOWS THE | | FOLLOWING BTU VALUES: | | POOL HEATER - 125,000 BTU'S | | DRYER - 22,000 BTU'S | | FIRELOGS - 32,000 BTU'S | | GENERATOR - 387,000 BTU'S | | NEW STOVE - 145,000 | | WATER HEATER??? WHERE IS THE BTU LOAD? | | TOTAL BTU LOAD - 711,000 ?? | | | | SUBMIT INFORMATION AS TO WHERE YOU OBTAINED THE BTU | | LOADS OF THE GAS APPLIANCES SHOWN ON YOUR DRAWINGS. | | THERE IS QUITE A DISCREPANCY IN THE LOADS OF APPLIANCES | | ON YOUR DRAWING. WPB AMEND. TO FBC SEC. 107.2.1, | | 107.3.5.3. | | 2) THE 3/4 INCH LINE TO THE NEW STOVE IS UNDERSIZED PER | | TABLE 402.4(2). THE MAXIMUM BTU LOAD ON A 3/4 INCH LINE | | AT 60 FEET IS 137,000 BTU'S. | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE RANGE | | THAT SHOWS THE CORRECT BTU LOAD. THE BURNERS ADD UP TO | | 62,200 BTU'S. WHAT IS THE BTU LOAD OF THE OVEN? THE GAS | | PLAN THAT HAS BEEN SUBMITTED SHOWS THE STOVE AT 145,000 | | BTU'S. CLARIFY. | | 4) THE STOVE SHALL BE LISTED AND LABELED PER 2017 FBC- | | FUEL GAS SEC.301.3. THE SUBMITTED SPECIFICATIONS DO NOT | | SHOW THIS. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|