Date |
Text |
2019-07-12 12:00:38 | BUILDING PLAN REVIEW - NFIP |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| BUILDING PLANS EXAMINER, PX3169 |
| 1&2 FAMILY PLANS EXAMINER, SFP306 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| |
| RESULTS: DENIED |
| |
| YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| BELOW. |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| NFIP REVIEW |
| CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 |
| |
| 1. BASED ON THE SUBMITTED SURVEY, THIS LOT AND PROPOSED |
| IMPROVEMENTS ARE LOCATED IN AN AE FLOOD ZONE WITH A |
| BASE FLOOD ELEVATION (BFE) OF 7.0 FEET NAVD. |
| 2. AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY |
| MANAGEMENT AGENCY (FEMA) ESTABLISHED A NEW FLOOD |
| INSURANCE RATE MAP (FIRM) UTILIZING THE RECENTLY |
| COMPLETED FLOOD HAZARD DETERMINATION (FHD) FOR THE CITY |
| OF WEST PALM BEACH, FL. |
| 3. ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED |
| ON NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST |
| PALM BEACH, BY ORDINANCE, ESTABLISHED A TWO FOOT |
| FREEBOARD ABOVE THE (BFE). |
| 4. YOU MAY SUBMIT A SURVEY SHOWING ALL EXISTING AND |
| PROPOSED ELEVATIONS BASED ON NAVD88 DATUM PLUS TWO FEET |
| OF FREEBOARD OR THE ENGINEER OF RECORD (EOR) MAY ADD A |
| STATEMENT TO THE STRUCTURAL PLAN THAT THE DESIGN FLOOD |
| ELEVATION (DFE) WILL BE 9.4 FEET NAVD88 BASED ON THE |
| (BFE) OF 7.00 FEET FOR FLOOD ZONE AE PLUS A CORRECTION |
| FACTOR OF .4 FEET PLUS TWO FEET OF FREEBOARD. |
| |
| A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS |
| REQUIRED AT TIME OF PERMIT APPLICATION. |
| NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS |
| SITE ARE REQUIRED TO BE AT OR ABOVE 9 FEET 4 INCHES |
| NAVD. |
| |
| AN UNDER CONSTRUCTION (FORMBOARD) SURVEY WITH FINISHED |
| FLOOR ELEVATION IS REQUIRED. |
| |
| A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS |
| REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL |
| PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. |
| THIS EC MAY BE SUBMITTED FOR REVIEW PRIOR TO BUILDING |
| FINAL. |
| |
| GARAGE - VENTS |
| |
| G1001.4 ENCLOSURES BELOW DESIGN FLOOD ELEVATION. |
| FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD ELEVATION |
| SHALL BE AT OR ABOVE GRADE ON ALL SIDES AND CONFORM TO |
| THE FOLLOWING: |
| |
| 1. IN FLOOD HAZARD AREAS NOT SUBJECT TO HIGH-VELOCITY |
| WAVE ACTION, ENCLOSED AREAS SHALL HAVE FLOOD OPENINGS |
| TO ALLOW FOR THE AUTOMATIC INFLOW AND OUTFLOW OF |
| FLOODWATERS. |
| |
| |
| |
| |
| |
| |