2019-05-21 08:57:12BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE
 OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE
 CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR,
 MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. CITY OF
 WPB CHAPTER 109.3
  
 2. SEPARATE ROOF PERMIT IS REQUIRED. SUBMIT ROOF
 PRODUCT APPROVALS WITH PERMIT. FBC 105
  
 3. PROVIDE ENGINEERED TRUSS SHOP DRAWINGS TO THE FIELD
 INSPECTOR. FBC 107
  
 4. PROVIDE WATER-RESISTIVE BARRIER TO THE NEW FACADE
 WALLS PER FBC 2510.6
  
 5. PROVIDE DOORS AND WINDOW DEFERRED SUBMITTALS
 APPROVED BY THE DESIGNER OF RECORD. FBC 107.3.4.2
  
 6. IN REGARDS THE NEW REAR FACADE WINDOW OPENINGS, NO
 STRUCTURAL DETAIL WAS PROVIDED FOR THE JAM. THE
 DRAWINGS STATE THIS IS AN EXISTING CMU WALL, HOWEVER IS
 THESE ARE HOLLOW BLOCKS, ARE GOING TO BE FILL WITH
 GROUT, IS A NEW REBAR GOING IN? PLEASE SPECIFY. FBC 107