2019-05-16 09:16:02 | 1ST REVIEW: 19050677 |
| |
| 2017 FLORIDA BUILDING CODE 6TH EDITION |
| 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| EDITION |
| |
| PLUMBING COMMENTS: |
| |
| 1. PLAN SHEETS SHALL BE SIGNED AND SEALED BY ENGINEER |
| LISTED ON TOP OF TITLE BLOCK LUIS C MAURY. PER FAC |
| 61G15-23.003 |
| |
| 2. VALUATION FOR THIS JOB APPEARS TO BE LOW PLEASE |
| PROVIDE A DETAILED, QUANTITY ESTIMATES, AND/OR BONA |
| FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO MEET |
| THE |
| APPROVAL OF THE BUILDING OFFICIAL. PER WPB AMEND TO FBC |
| 109.3 |
| |
| 3. SHT A1 THE PROPOSED FLOOR PLAN SHOWS AN EXISTING |
| WATER HEATER SHT E1 SHOWS A NEW TANKLESS AND THE |
| EXISTING TANK TYPE WATER HEATER IS THE OLD HEATER |
| REMAINING IN USE PLEASE CLARIFY. PER WPB AMEND TO FBC |
| 107.2.1 |
| |
| 4. PLEASE PROVIDE DIMENSIONS OF THE SHOWER SHALL COMPLY |
| WITH FBC RES P2708.1 |
| |
| 5. PLEASE SHOW CLEANOUT ON THE ISOMETRIC DRAWING WERE |
| THE NEW BUILDING DRAIN EXISTS THE STRUCTURE. PER FBC |
| RES P3005.2.3 |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. |
| |
| |