Plan Review Notes
Plan Review Notes For Permit 19050673
Permit Number 19050673
Review Stop P
Sequence Number 1
Notes
Date Text
2019-05-22 17:12:58PLUMBING 1ST REVIEW**DEINIED**
  
 1) WASHING MACHINE IS NOT PERMITTED TO DISCHARGE INTO
 THE BATHROOM GROUP HORIZONTAL WET VENT AS SHOWN ON SHT
 2. FBC-PLB 912.1, 912.2.1
  
 2) WASHING MACHINE HORIZONTAL BRANCH PIPE SHALL BE MIN
 3". FBC-PLB 406.2
  
 3) PROVIDE COMPLETE MANUFACTURES INSTALLATION MANUAL
 FOR THE WASHER/DRYER. FBC 107.2.1
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR