2019-05-06 09:37:16 | RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW |
| CHECKLIST. |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER, |
| THE VALUE OF THE STRUCTURE IS $319,214. THEREFORE, |
| NEEDS TO COMPLY WITH THE ROOF TO WALL CONNECTIONS AS |
| REQUIRED BY SEC. 706.8 FBC-EXISTING BUILDING. SHOW |
| COMPLIANCE. NOTE: A SEPARATE SUB-PERMIT IS REQUIRED FOR |
| ROOF TO WALL CONNECTIONS. THIS WORK CAN NOT BE DONE BY |
| THE ROOFING CONTRACTOR UNLESS ROOFING CONTRACTOR |
| POSSESSES THE PROPER LICENSE TO PERFORM THIS WORK. |
| |
| RESPONSE: |
| CONTRACTOR SUBMITTED COPY OF WIND MITIGATION |
| INSPECTION. THE REPORT SHOWS TOE NAILS AS THE ROOF TO |
| WALL CONNECTION. CONTRACTOR NEEDS TO PROVIDE |
| INFORMATION SHOWING HOW ADDRESSING THE ROOF TO WALL |
| CONNECTION REQUIRED BY SEC. 706.8. |
| NOTE: TALKED TO DIANA TO EXPLAIN THE INFORMATION WE |
| NEED TO HAVE TO SHOW COMPLIANCE. |
| |
| 2- ENGINEERING SUBMITTED FOR FLAT ROOF: |
| A) OK. |
| |
| B) OK |
| |
| C) OK |
| |
| 3- OK |
| |
| 4- OK |
| |
| 5-- ROOFING UNDERLAYMENT FLORIDA PRODUCT APPROVALS |
| FL14317-R10 SUBMITTED: |
| A) CLEARLY MARK WHICH MAXIMUM DESIGN PRESSURES ASSEMBLY |
| FORM SEC. 5.6.4 OF PRODUCT APPROVAL IS GOING TO BE |
| USED. OR IF USING THE FRSA/TRI APRIL 2012 (04-12) |
| REVISED EDITION, THEN PROVIDE COMPLETE INFORMATION |
| SHOWING THE DETERMINATION OF DESIGN WIND LOADS AS |
| REQUIRED BY SEC. 5.6.4. |
| |
| RESPONSE: |
| ONLY COPY OF TABLE 1A OF FRSA/TRI SHOWING THE DESIGN |
| PRESSURES WAS SUBMITTED. IT IS NOT CLEAR IF CONTRACTOR |
| IS USING THE FRSI INSTALLATION GUIDELINES OR IF USING |
| ANY OF THE SYSTEMS LISTED ON SEC. 5.6.4 OF FLORIDA |
| PRODUCT APPROVAL SUBMITTED. IF USING ANY SYSTEM FROM |
| THE PRODUCT APPROVAL, THEN CLEARLY MARK WHICH ONE. IF |
| USING THE FRSA INSTALLATION GUIDELINES, THEN PROVIDE |
| COMPLETE INFORMATION FROM THE FRSA GUIDELINES SHOWING |
| UNDERLAYMENT INSTALLATION. |
| NOTE: TALKED TO DIANA TO EXPLAIN HOW TO ADDRESS THIS |
| COMMENT. |
| |
| 6- OK |
| |
| 7- OK |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| |