2019-05-01 17:34:54BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. VALUE HAS BEEN ADJUSTED FRO 120000 TO 173580 BASED
 ON THE ICC BUILDING VALUATION DATA PUBLISHED FEB. 2019.
 CITY OF WPB CHPT. 1 VALUE
 109.3 BUILDING PERMIT VALUATIONS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
 2. PROVIDE SITE DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3
  
 3. DESIGN PROFESSIONALS SIGNATURE AND SEAL ON SOILS
 REPORT IS INVALID.
 PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE,
 DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE
 61G15-23.001.
  
 4. PROVIDE SITE PLAN.
 107.2.5 SITE PLAN.
  
 5. BUILDING ORIENTATION TO CARDINAL NORTH ON PLAN PAGE
 A-1 IS INCORRECT.
 FBC 107.2.1 & FBC ENERGY CONSERVATION R405.4.2.1
  
 6. PROVIDE PRODUCT SPECIFICATIONS AND INSTALLATION
 INSTRUCTIONS FOR THE PROPOSED ICYNENE INSULATION.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 7. PROVIDE DETAIL FOR ALL WELDED CONNECTIONS.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 8. SHOW FINISHED FLOOR ELEVATION ON SITE PLAN/FLOOR
 PLAN.
 R403.1.7.3 FOUNDATION ELEVATION.
  
 9. BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 10. GUTTERS REQUIRED.
 R318.5PROTECTION AGAINST DECAY AND TERMITES.
 GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS
 WITH EAVES OF LESS THAN 6 INCHES (152 MM) HORIZONTAL
 PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF
 ABOVE ANOTHER ROOF
  
 11. FBC 107.3.5.3 ? INDICATE THE MEANS OF TERMITE
 PROTECTION PROPOSED PURSUANT TO FBC-R318.
  
 12. INCREASE OPENING PRESSURE TO CORRESPOND WITH THE
 20FT. MRH PER FBC R301.2.1.
  
 13. NOA 17-0130.04 ELASTATITE G 20140 IS FOR ROOF TILE.
 REMOVE FROM SUBMITTAL.
  
 14. IDENTIFY ROOFING SYSTEM COMPONENTS TO BE USED ON
 PAGE 3 OF 4 OF THE TRINITY EVALUATION REPORT.
  
 15. PROVIDE TYPICAL EXTERIOR DOOR FRAMING DETAIL.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 16. EXTERIOR CLADDING (STUCCO) SHALL TERMINATE 6 INCHES
 ABOVE FINISHED GRADE.
 R318.7 INSPECTION FOR TERMITES.
 IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS
 AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6 INCHES (152 MM).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
 THE FOLLOWING PROVISOS WILL BE PLACED ON THE PLANS FOR
 FIELD VERIFICATION:
 1. WELDER CERTIFICATIONS.
 2. INSTALLATION INSTRUCTIONS FOR ICYNENE INSULATION.
  
  