Plan Review Notes
Plan Review Notes For Permit 19040110
Permit Number 19040110
Review Stop B
Sequence Number 2
Notes
Date Text
2019-05-06 08:58:35RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL1654-R22
 SUBMITTED:
 A) SELECTED ASSEMBLY W-104 DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES. NEED TO PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS AS REQUIRED BY
 LIMITATION #5.7 ON PAGE 5 OF 6 OF PRODUCT APPROVAL
 SUBMITTED. NEED THE CALCULATIONS TO MEET THE DESIGN
 PRESSURES REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: CONTRACTOR MAY SELECT ANOTHER ASSEMBLY THAT MEETS
 THE DESIGN PRESSURES FOR ALL ROOF ZONES AND RAS 117
 CALCULATIONS ARE NOT REQUIRED.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 B) PROVIDE CURRENT FLORIDA PRODUCT APPROVAL. CURRENT
 FLORIDA PRODUCT APPROVAL IS FL1654-R23 NOT FL1654-R22.
 FAC 61G20-3.001.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 C) PROVIDE COMPLETE FLORIDA PRODUCT APPROVAL. PRODUCT
 APPROVAL SUBMITTED IS MISSING THE FLORIDA PRODUCT
 APPROVAL COVER PAGE. THIS PAGE IS REQUIRED BECAUSE IT
 SHOWS THE CURRENT CODE VERSION AND THE PRODUCT APPROVAL
 STATUS. CHAPTER 553 F.S. AND FAC 61G20-3.001.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 2- METAL ROOFING PANELS WERE CHANGED TO SHINGLES
 BECAUSE HISTORIC DOESN'T ALLOW METAL ROOFING PANELS.
 THE FOLLOWING REQUIRED INFORMATION WAS NOT SUBMITTED AS
 REQUESTED ON PREVIOUS CHECKLIST:
  
 A) SPECIFY ROOF PITCH AND ROOF MEAN ROOF HEIGHT AS
 REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS AND
 SEC. R905.10.2 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 B) PROVIDE COMPLETE FLORIDA PRODUCT APPROVAL. PRODUCT
 APPROVAL SUBMITTED IS MISSING THE FLORIDA PRODUCT
 APPROVAL COVER PAGE. THIS PAGE IS REQUIRED BECAUSE IT
 SHOWS THE CURRENT CODE VERSION AND THE PRODUCT APPROVAL
 STATUS. CHAPTER 553 F.S. AND FAC 61G20-3.001.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 3- ROOF UNDERLAYMENT FL21895-R2 SUBMITTED: PROVIDE
 COMPLETE FLORIDA PRODUCT APPROVAL. PRODUCT APPROVAL
 SUBMITTED IS MISSING THE FLORIDA PRODUCT APPROVAL COVER
 PAGE. THIS PAGE IS REQUIRED BECAUSE IT SHOWS THE
 CURRENT CODE VERSION AND THE PRODUCT APPROVAL STATUS.
 CHAPTER 553 F.S. AND FAC 61G20-3.001.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 4- THERE IS MORE THAN ONE STRUCTURE IN THIS PROPERTY.
 PROVIDE MAP OR SKETCH SHOWING LOCATION OF AREA OF WORK
 AND SQUARE FOOTAGE OF EACH AREA (PITCH AND FLAT) AS
 REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS AND
 SEC. 107.02.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WILL BE RE-EVALUATED ONCE THE
 ROOFING AREAS ARE PROVIDED.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  