2019-06-11 15:20:55 | CODES IN EFFECT: |
| FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| 6TH ED, CHAPTER 1. |
| WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| MANUAL REVISED 2017 |
| FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| 6TH EDITION |
| FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| EDITION |
| FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| NFPA 30A |
| FAC= FLORIDA ADMINISTRATIVE CODE |
| FS = FLORIDA STATUTES |
| |
| |
| 2ND REVIEW |
| PLUMBING COMMEMTS: DENIED |
| |
| REGARDING THE RESPONSE LETTER (REF: PERMIT |
| 17020652-RESPONSE LETTER), PLUMBING COMMENT RESPONSE |
| THAT THE REVISED PLUMBING RISER IS ON SHEET E-1 IS NOT |
| ACCURATE. THERE IS NO REVISED PLUMBING RISER ON E-2. IF |
| THERE IS TO BE A REVISED RISER DIAGRAM ON E-2, THEN THE |
| DIAGRAM ON S-2 SHALL BE REMOVED. |
| AS THERE IS NO REVISED DRAWING IT APPEARS NO ACTION HAS |
| BEEN TAKEN IN RESPONSE TO THE COMMENTS MADE IN THE |
| FIRST REVIEW. PLEASE SEE BELOW. |
| |
| 1. SHT. S-1 AND S-2 THE SEAL AND SIGNATURE OF THE |
| ENGINEER APPEARS TO BE PHOTO COPIED THEY SHALL BE |
| ORIGINAL. FAC 61G15-23.003 |
| 2. REMOVE STAMP AND SIGNATURE OF PREVIOUS PLUMBING |
| EXAMINER SHT. S-2 PER WPB AMEND TO FBC 107.2.1 |
| 3. SHT S-2 THE PLUMBING SANITARY RISER IN THE BATHROOM |
| GROUP ONLY ONE FIXTURE UP STREAM OF THE WET VENT IS |
| ALLOWED THE LAVATORY SHALL CONNECT BETWEEN THE TOILET |
| AND TUB. PER FBC RES P3108.2.1 |
| |
| END OF COMMENTS. |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED |
| AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| |
| |
| |
| JERALD SMITH |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| EMAIL [email protected] |
| PHONE 561-805-6715 |
| |
| 19031173 3212 GREENWOOD AVE |