2019-05-20 09:13:55 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | JOSEAN A. DUPREY | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6716 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL APPROVAL FOR THE SUBMITTED SCOPE OF WORK | | IS PENDING DUE FOR THE REASONS LISTED BELOW. | | | | 1. PER PALM BEACH COUNTY PROPERTY APPRAISAL WEBSITE | | THIS PROPERTY HAVE A TOTAL OF 2932 SQUARE FOOT. THE | | ENERGY CALCULATIONS WERE SUBMITTED WITH A TOTAL OF 1818 | | SQUARE FOOT AND A TOTAL OF 4 BEDROOMS, PLEASE CLARIFY. | | ALSO THE LINE ITEM NUMER 9 IS ONLY INCLUDING ONE TYPE | | OF WALL (CONCRETE BLOCK) WITH INSULATION TYPE R4.1, | | HOWEVER THE DRAWING DETAIL 3/A2.0 SHOW AN INSULATION | | TYPE R5 FOR THIS CONCRETE WALL TYPE. THE ENERGY | | CALCULATION DOCUMENT DOES NOT SHOW INSULATION | | REQUIREMENTS FOR UPPER FLOOR WOOD WALLS AS INDICATE ON | | DETAIL 3/A2.0. PLEASE CLARIFY AND RE-SUBMIT. | | | | | | |
|