2019-03-07 14:55:16 | BUILDING PLAN REVIEW |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| JOSEAN A. DUPREY E.I., BN, PX |
| BUILDING PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6716 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| BELOW. |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE |
| OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE |
| COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED |
| CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE |
| CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR, |
| MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. CITY OF |
| WPB CHAPTER 109.3 |
| |
| 2. PROVIDE STUCCO DETAIL, THIS MUST MEET FBC R703.7.3 |
| WATER-RESISTIVE BARRIERS. |
| WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED |
| IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED |
| SHEATHING, SHALL INCLUDE A WATER-RESISTIVE |
| VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST |
| EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE |
| INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH |
| THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE |
| AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION |
| R703.4) INTENDED TO DRAIN TO THE WATER-RESISTIVE |
| BARRIER IS DIRECTED BETWEEN THE LAYERS. |
| EXCEPTION: WHERE THE WATER-RESISTIVE BARRIER THAT IS |
| APPLIED OVER WOOD-BASED SHEATHING HAS A WATER |
| RESISTANCE EQUAL TO OR GREATER THAN THAT OF 60-MINUTE |
| GRADE D PAPER AND IS SEPARATED FROM THE STUCCO BY AN |
| INTERVENING, SUBSTANTIALLY NONWATER-ABSORBING LAYER OR |
| DESIGNED DRAINAGE SPACE. |
| |