Plan Review Notes For Permit 19021432 |
Permit Number |
19021432 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2019-03-04 04:48:51 | `1) I AM QUESTIONING THE VALUE OF THIS JOB AT $1500.00. | | SUBMIT DETAILED, QUANTITY ESTIMATES OR A BONA FIDE | | SIGNED CONTRACT SHOWING THE TOTAL VALUE OF THE ENTIRE | | SCOPE OF WORK TO BE DON4, | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE WATER | | HEATER TO BE INSTALLED. IS IT GAS OR ELECTRIC? INDICATE | | ON THE PLAN. WPB AMEND. TO FBC SEC. 107.2.1. | | 3) THE TUB/SHOWER VALVE SHALL BE BALANCED-PRESSURE, | | THERMOSTATIC OR COMBINATION | | BALANCED-PRESSURE/THERMOSTATIC VALVES THATCONFORM TO | | THE REQUIREMENTS OF ASSE 1016/ASME A112.1016 OR ASME | | A112.18.1/CSA B125.1. | | 4) INDICATE ON THE PLAN IF ANY OF THE PLUMBING FIXTURES | | ARE BEING RELOCATED. IF NOT, ,PLACE A NOTE ON THE PLANS | | THAT THE PLUMBING FIXTURES ARE BEING REPLACED IN THEIR | | ORIGINAL LOCATION. WPB AMEND. TO FBC SEC 107.2.1. | | 5) SUBMIT TWO SETS OF THE FLOOR PLANS FOR REVIEW. WPB | | AMEND. TO FBC SEC. 107.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|