2019-02-11 17:54:26 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| 1- ROOF TILE UNDERLAYMENT FLORIDA PRODUCT APPROVAL |
| FL10450-R10 SUBMITTED. CLEARLY SPECIFY IF THE |
| UNDERLAYMENT IS GOING TO BE A DIRECT-DECK UNDERLAYMENT |
| OR MECHANICALLY ATTACHED BASE SHEET. THEN THE FOLLOWING |
| IS REQUIRED: |
| |
| A) FOR DIRECT-BOND TO DECK SEE NOTE AT BOTTOM OF SEC. |
| 5.6.1 AND CLEARLY IDENTIFY WHICH ASSEMBLY FROM SEC. |
| 5.6.4 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE |
| WITH THE DESIGN PRESSURES OF SEC. R301.1 |
| FBC-RESIDENTIAL. NOTE: IF SELECTED ASSEMBLY DOESN'T |
| MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN IT |
| CAN NOT BE USED. |
| |
| B) FOR MECHANICALLY ATTACHED BASE SHEET SEE SECTION |
| 5.6.2 AND PROVIDE MINIMUM FASTENING REQUIREMENTS FROM |
| FRSA/TRI APRIL 2012 (04-12), APPENDIX A, TABLE 1. |
| CLEARLY MARK TABLE 1 WITH PROPOSED FASTENING. |
| |
| 2- CLEARLY IDENTIFY ON PRODUCT APPROVALS THE ROOF TILE |
| PROFILE AND PADDY SIZE AS REQUIRED BY CITY POLICY FOR |
| ALL ROOFING PERMITS. |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE |
| PREVIOUSLY REVIEWED SHEETS. |
| PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD |
| DRAWINGS/DOCUMENTS FOR REFERENCE. |
| |