2019-02-25 13:14:56 | ****CORRECTIONS**** |
| |
| PETER E VALENTI |
| BUILDING PLANS EXAMINER |
| [email protected] |
| 561-805-6673 |
| |
| FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| FBC B = FBC BUILDING |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| FBC R = FBC RESIDENTIAL |
| |
| THE ITEMS FROM LAST REVIEW (NOTED BELOW) HAVE NOT BEEN |
| ADDRESSED. PLEASE REVIEW AND ADDRESS THE NOTED ITEMS: |
| |
| 1 ROOFING CONTRACTOR SUBMITTED FLORIDA PRODUCT |
| APPROVAL FOR SKYLIGHTS. SCOPE OF WORK IS NOT CLEAR. |
| ACCORDING TO CITY RECORDS, THIS HOUSE HAD NOT SKYLIGHTS |
| AT TIME OF CONSTRUCTION AND THERE ARE NOT RECORDS FOR |
| PERMIT APPLICATIONS FOR SKYLIGHT INSTALLATION. ALSO, |
| PAPA AERIAL VIEW DOESN'T SHOW SKYLIGHTS EITHER. FRAMING |
| AND INSTALLATION OF SKYLIGHTS CAN NOT BE DONE BY THE |
| ROOFING CONTRACTOR UNLESS ROOFING CONTRACTOR POSSES A |
| LICENSE TO DO SO. SEE SEC. 489.113 F.S. NEED TO PROVIDE |
| COMPLETE FRAMING DETAILS AND SPECIFICATIONS FOR THE NEW |
| SKYLIGHT, INCLUDING LOCATION ON THE ROOF. AND, NEED |
| SEPARATE PERMIT OR SUB-PERMIT APPLICATION FOR THIS |
| ADDITIONAL SCOPE OF WORK. |
| |
| 2 ROOF TILE UNDERLAYMENT FLORIDA PRODUCT APPROVAL |
| FL10450 R10 SUBMITTED. CLEARLY SPECIFY IF THE |
| UNDERLAYMENT IS GOING TO BE A DIRECT DECK UNDERLAYMENT |
| OR MECHANICALLY ATTACHED BASE SHEET. THEN THE FOLLOWING |
| IS REQUIRED: |
| A) FOR DIRECT BOND TO DECK SEE NOTE AT BOTTOM OF SEC. |
| 5.6.1 AND CLEARLY IDENTIFY WHICH ASSEMBLY FROM SEC. |
| 5.6.4 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE |
| WITH THE DESIGN PRESSURES OF SEC. R301.1 |
| FBC RESIDENTIAL. NOTE: IF SELECTED ASSEMBLY DOESN'T |
| MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN IT |
| CAN NOT BE USED. |
| B) FOR MECHANICALLY ATTACHED BASE SHEET SEE SECTION |
| 5.6.2 AND PROVIDE MINIMUM FASTENING REQUIREMENTS FROM |
| FRSA/TRI APRIL 2012 (04 12), APPENDIX A, TABLE 1. |
| CLEARLY MARK TABLE 1 WITH PROPOSED FASTENING. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |