2019-02-11 18:11:14RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOFING CONTRACTOR SUBMITTED FLORIDA PRODUCT
 APPROVAL FOR SKYLIGHTS. SCOPE OF WORK IS NOT CLEAR.
 ACCORDING TO CITY RECORDS, THIS HOUSE HAD NOT SKYLIGHTS
 AT TIME OF CONSTRUCTION AND THERE ARE NOT RECORDS FOR
 PERMIT APPLICATIONS FOR SKYLIGHT INSTALLATION. ALSO,
 PAPA AERIAL VIEW DOESN'T SHOW SKYLIGHTS EITHER. FRAMING
 AND INSTALLATION OF SKYLIGHTS CAN NOT BE DONE BY THE
 ROOFING CONTRACTOR UNLESS ROOFING CONTRACTOR POSSES A
 LICENSE TO DO SO. SEE SEC. 489.113 F.S. NEED TO PROVIDE
 COMPLETE FRAMING DETAILS AND SPECIFICATIONS FOR THE NEW
 SKYLIGHT, INCLUDING LOCATION ON THE ROOF. AND, NEED
 SEPARATE PERMIT OR SUB-PERMIT APPLICATION FOR THIS
 ADDITIONAL SCOPE OF WORK.
  
 2- ROOF TILE UNDERLAYMENT FLORIDA PRODUCT APPROVAL
 FL10450-R10 SUBMITTED. CLEARLY SPECIFY IF THE
 UNDERLAYMENT IS GOING TO BE A DIRECT-DECK UNDERLAYMENT
 OR MECHANICALLY ATTACHED BASE SHEET. THEN THE FOLLOWING
 IS REQUIRED:
  
 A) FOR DIRECT-BOND TO DECK SEE NOTE AT BOTTOM OF SEC.
 5.6.1 AND CLEARLY IDENTIFY WHICH ASSEMBLY FROM SEC.
 5.6.4 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL. NOTE: IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN IT
 CAN NOT BE USED.
  
 B) FOR MECHANICALLY ATTACHED BASE SHEET SEE SECTION
 5.6.2 AND PROVIDE MINIMUM FASTENING REQUIREMENTS FROM
 FRSA/TRI APRIL 2012 (04-12), APPENDIX A, TABLE 1.
 CLEARLY MARK TABLE 1 WITH PROPOSED FASTENING.
  
 3- CLEARLY IDENTIFY ON PRODUCT APPROVALS THE ROOF TILE
 PROFILE AND PADDY SIZE AS REQUIRED BY CITY POLICY FOR
 ALL ROOFING PERMITS.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  