2019-02-26 08:04:59 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 19020144 |
| ADD: 501 S. FLAGLER DR. 2ND FLOOR COMMON AREAS |
| CONT: ANDERSON MOORE |
| TEL: 561-348-4805 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. FEB.26/ 2019 |
| ACTION: DENIED |
| |
| 1) SHEET 002_LS1.0 THE LIFE SAFETY SHEET UNDER THE |
| HEADING CODE ANALYSIS INDICATES THE CONSTRUCTION TYPE |
| AS 1A. PLEASE NOTE ON THIS SITE THERE ARE 2 BUILDINGS A |
| HIGHRISE AND A 6 STORY BUILDING. THE APPLICATION NOR |
| THE LIFE SAFETY PLAN INDICATE WHERE THIS WORK IS TO BE |
| COMPLETED, IN THE HIGH RISE WHICH WOULD REQUIRE AN |
| ELEVATOR LOBBY OR IN THE 6 STORY BUILDING? UNDER A |
| INTERIOR DEMO PERMIT FOR THIS SITE 18070378 REV. # 1 |
| INDICATES IN THAT PERMIT THE WORK IS IN THE 6 STORY |
| BUILDING NOT REQUIRING A ELEVATOR LOBBY. ADDITIONAL |
| INFORMATION IS REQUIRED. 107.2.1.2. 2017 FBC-B ELEVATOR |
| LOBBIES: 403.6.2 & 30.8. |
| |
| 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |