2019-01-28 12:21:40 | 1ST REVIEW: 18120892 |
| 2017 FLORIDA BUILDING CODE 6TH EDITION |
| 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| EDITION |
| |
| PLUMBING COMMENTS: |
| |
| 1. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.7 TOILET |
| PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND SHALL BE 7 |
| INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE |
| WATER CLOSET MEASURED TO THE CENTERLINE OF THE |
| DISPENSER. |
| |
| 2. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.2 THE WATER |
| CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION TO |
| THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE WATER |
| CLOSET SHALL BE 16 INCHES MINIMUM TO 18 INCHES MAXIMUM |
| FROM THE SIDE WALL OR PARTITION. |
| |
| 3. A OVERFLOW ROOF DRAIN OR SCUPPER IS REQUIRED. PER |
| FBC PL 1108.1 |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. |
| |