2019-03-12 17:44:19 | RESIDENTIAL (R3) ROOFING FIFTH BUILDING REVIEW |
| CHECKLIST. |
| CODE: FBC 5TH EDITION (2016) AND CITY AMENDMENTS. |
| |
| ORIGINAL COMMENT: |
| 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL16709-R4 |
| SUBMITTED: |
| A) SELECTED ASSEMBLY W-2 IS FOR AN INSULATED FLAT ROOF |
| ASSEMBLY. APPROVED PLANS DON'T SPECIFY INSULATED |
| ASSEMBLIES. APPROVED PLANS SPECIFY ICYNENE FOAM |
| INSULATION NOT FLAT ROOF INSULATED ASSEMBLY. REVISE AS |
| REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. |
| NOTE: COORDINATE WITH ARCHITECT TO AVOID |
| CONFLICTS/DELAYS. |
| |
| RESPONSE: |
| REPEAT COMMENT. PLANS DON'T CALL FOR ROOF INSULATION |
| OTHER THAN THE FOAM INSULATION. SEE PLANS. OTHERWISE, |
| PLANS NEED TO BE REVISED SHOWING THE FLAT ROOF |
| INSULATION SHOWN ON THE SELECTED FLAT ROOF ASSEMBLY. |
| |
| ORIGINAL COMMENT: |
| B) SELECTED ASSEMBLY CAN NOT BE USED. THE INSULATION |
| ATTACHMENT FOR CORNER AREA (ROOF ZONE #3) IS NOT |
| APPLICABLE (N/A). SEE PAGE 8 OF 14 OF PRODUCT APPROVAL |
| SUBMITTED. REVISE AS REQUIRED. COORDINATE WITH ITEM |
| #1(A) ABOVE. |
| SEC. R301.1 FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| NOTE: COORDINATE WITH ITEM ABOVE. |
| |
| ORIGINAL COMMENT: |
| 2- CLEARLY SPECIFY WHICH POLYGLASS ROOFING UNDERLAYMENT |
| FROM FLORIDA PRODUCT APPROVAL FL5259-R28 SUBMITTED IS |
| GOING TO BE USED TO VERIFY COMPLIANCE WITH PROPOSED |
| INSTALLATION. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| |
| 3- OK. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE |
| PREVIOUSLY REVIEWED SHEETS. |
| PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD |
| DRAWINGS/DOCUMENTS FOR REFERENCE. |
| |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |