2019-01-07 18:51:48NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- IT LOOKS LIKE THE 1415 N. SAPODILLA ADDRESS MAY NEED
 TO BE CHANGED WITH AN APPROVED ADDRESS IDENTIFICATION
 AS REQUIRED BY SEC. R319.1 FBC RESIDENTIAL.
 TYPICALLY, THE ADDRESS IS GIVEN BASED ON THE STREET
 FACING THE ENTRY OF THE BUILDING. THE PROPOSED BUILDING
 ENTRANCE IS FACING 14TH STREET. THERE WERE THREE
 BUILDINGS IN THIS PARCEL AND THEY WERE DEMOLISHED. THE
 ADDRESS FOR THE BUILDING FACING 14 STREET WAS 702 14TH
 STREET. IT LOOKS LIKE THE 702 14TH STREET ADDRESS WILL
 BE MORE SUITABLE. PLEASE CONTACT MIKE ORIO CITY OF WEST
 PALM BEACH GIS SUPPORT SPECIALIST TO GET APPROVED
 ADDRESS.
 SEE CONTACT INFORMATION BELOW.
  
  
 CONTACT: MICHAEL ORIO GIS SUPPORT SPECIALIST/
 INFORMATION TECHNOLOGY
 TEL: 561-494-1040
 E-MAIL: [email protected]
  
  
 2-IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
 3- A)SURVEY NEEDS TO SPECIFY WHAT REFERENCE WAS USED TO
 DETERMINE THE ELEVATIONS. NORTH AMERICAN VERTICAL DATUM
 OF 1988?. SEC. 107.2.1 CITY AMENDMENTS.
  
 B) PROVIDE SURVEY WITH SURVEYORS ORIGINAL SEAL AND
 SIGNATURE AS REQUIRED BY CHAPTER 472 F.S. OR SUBMIT
 SURVEY WITH DIGITAL SIGNATURE.
  
 4- REVISE ENERGY CALCULATIONS:
 A) ITEM #5 ON PAGE 1 OF 5 STATES THAT THIS IS NOT WORST
 CASE SCENARIO. PAGE 2 OF 4 STATES THAT THE HOUSE WAS
 ROTATED 180 DEGREES. CALCULATIONS NEED TO BE DONE BASED
 ON THE ACTUAL ORIENTATION OF THE BUILDING OR PROVIDE
 THE CALCULATIONS FOR WORST CASE SCENARIO AS ALLOWED BY
 THE EXCEPTION ON SEC. R405.4.2.1 FBC-ENERGY
 CONSERVATION. REVISE AS REQUIRED.
  
 B)WALL INSULATION DOESN'T MATCH PLANS.
  
 C) PROVIDE THE NAME OF THE OWNER. REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) PROVIDE THE NAME OF THE PERSON PERFORMING THE ENERGY
 CALCULATIONS. REVISE AS REQUIRED. SEC. R405.4.2.1
 FBC-ENERGY CONSERVATION.
  
 E) EXTERIOR DOORS ORIENTATION DON'T MATCH PLANS. EVEN
 IF DOING CALCULATIONS FOR WORST CASE SCENARIO. REVISE
 AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 F)WINDOWS INFORMATION IS INCORRECT. REVISE THE WINDOW
 ORIENTATION, WINDOW AREA AND WINDOW OVERHANG DEPTH AND
 SEPARATION TO MATCH PLANS. REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 G) PROVIDE MANUFACTURER'S INFORMATION SHOWING THE
 WINDOWS EFFICIENCIES SPECIFIED ON THE FIRST PAGE OF THE
 ENERGY CALCULATIONS AS REQUIRED BY SEC. R405.4.3
 FBC-ENERGY CONSERVATION.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE SHGC FACTOR
 SPECIFIED IN THE ENERGY CALCULATIONS WILL BE REQUIRED
 FOR INSPECTION.
  
 5- UNABLE TO SEE SOIL TEST REPORT. IT WAS NOT UPLOADED.
 PROVIDE SOIL TEST REPORT. SEC. R401.4 FBC-RESIDENTIAL.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR OR DESIGN PROFESSIONAL TO LIST THE FLORIDA
 PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED
 CONNECTOR.
  
 7- VALUATION DECLARED IN THE PERMIT APPLICATION WAS
 UPDATED TO $184,578. AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. THE PERMIT FEE BALANCE IS $1,841.08.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]