Plan Review Notes
Plan Review Notes For Permit 18110238
Permit Number 18110238
Review Stop Z
Sequence Number 1
Notes
Date Text
2018-12-04 15:04:07FAILED
  
 1) THE MOST RECENT SITE PLAN IS NOT BEING USED FOR THE
 AREA AROUND THE COMPACTOR. THE LOCATION OF THE PROPOSED
 PEDESTRIAN GATE HAS BEEN SHIFTED TO THE WEST.
  
 2) THE CITY DOES NOT PERMIT CHAIN LINK WITH SLATS. THE
 GATES SHOWING THIS CONDITION MUST BE REVISED TO COMPLY
 WITH CITY CODE.
  
 3) THE FENCE DETAILS ARE NOT CLEAR ON THE OVERALL
 HEIGHT OF THE GATE SUPPORT COLUMNS. PAGE 3 OF 3 SHOWS A
 6 INCH GAP AT THE GROUND WITH A 5 FOOT 6 INCH GATE.
 THERE IS NO DIMENSION SHOWN TO THE TOP OF THE SUPPORT
 POSTS. BY CITY CODE THESE MAY ONLY BE 6 FEET IN HEIGHT,
 WITH THE ALLOWANCE OF AN ADDITIONAL 10% FOR
 ARCHITECTURAL FEATURES. THIS WOULD PERMIT THE OVERALL
 HEIGHT OF THE SUPPORT POSTS, PLUS CAPS, TO BE 79
 INCHES. PLEASE PROVIDE A DIMENSION LINE TO VERIFY THAT
 THE OVERALL HEIGHT DOES NOT EXCEED 79 INCHES.
  
 4) THE PROPOSED FENCE/GATES CROSS GENERAL UTILITY AND
 FPL EASEMENTS. PROVIDE ALL THE EASEMENT RELEASES.
  
 5) THE FENCES AND OKEECHOBEE BOULEVARD GATES COMPLY
 WITH CODE REQUIREMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]