Plan Review Notes
Plan Review Notes For Permit 18110168
Permit Number 18110168
Review Stop B
Sequence Number 1
Notes
Date Text
2018-12-06 10:02:23 
 ****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1.PLEASE PROVIDE PRODUCT APPROVALS FOR ROOF TILES AND
 UNDERLAYMENT/BASE MATERIAL. FBC 107.1
 2.PLEASE PROVIDE MANUFACTURER?S INSTRUCTIONS FOR THE
 VENTED HOOD AND GAS GRILL SHOWN IN SHEET 1. FBC 107.1
 3.PROVIDE LOCATION WITH ATTACHMENTS DETAILS AND EXHAUST
 LOCATION(INCLUDING TERMINATION) FOR THE VENTED HOOD.
 FBCR 1307.1 AND 1307.2
 4.THE STUCCO DETAIL NEEDS ADDITIONAL LAYER OF WATER
 BARRIER.
 R703.7.3 WATER-RESISTIVE BARRIERS.
 WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED
 IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED
 SHEATHING, SHALL INCLUDE A WATER-RESISTIVE
 VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST
 EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE
 INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH
 THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE
 AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION
 R703.4) INTENDED TO DRAIN TO THE WATER-RESISTIVE
 BARRIER IS DIRECTED BETWEEN THE LAYERS.
 EXCEPTION: WHERE THE WATER-RESISTIVE BARRIER THAT IS
 APPLIED OVER WOOD-BASED SHEATHING HAS A WATER
 RESISTANCE EQUAL TO OR GREATER THAN THAT OF 60-MINUTE
 GRADE D PAPER AND IS SEPARATED FROM THE STUCCO BY AN
 INTERVENING, SUBSTANTIALLY NONWATER-ABSORBING LAYER OR
 DESIGNED DRAINAGE SPACE.
 5.PLEASE PROVIDE DECK RAFTERS SIZE. FBC 107.2
 6.PLEASE PROVIDE THE SPACING FOR THE #5 FILL CELLS
 REBAR. FBC 107.2.1
  