Plan Review Notes
Plan Review Notes For Permit 18110093
Permit Number 18110093
Review Stop P
Sequence Number 3
Notes
Date Text
2019-06-04 08:56:32PLUMBING NOTE:
  
 THE VENT FOR THE BAR AREA THRU THE SIDE WALL SHALL
 COMPLY WITH.
 FBC PL 903.6 EXTENSION THROUGH THE WALL.
 VENT TERMINALS EXTENDING THROUGH THE WALL SHALL
 TERMINATE AT A POINT NOT LESS THAN 10 FEET (3048 MM)
 FROM A LOT LINE AND NOT LESS THAN 10 FEET (3048 MM)
 ABOVE AVERAGE GROUND LEVEL. VENT TERMINALS SHALL NOT
 TERMINATE UNDER THE OVERHANG OF A STRUCTURE WITH SOFFIT
 VENTS. SIDE WALL VENT TERMINALS SHALL BE PROTECTED TO
 PREVENT BIRDS OR RODENTS FROM ENTERING OR BLOCKING THE
 VENT OPENING.
  
  
 A) SEPARATE PERMIT IS REQUIRED FOR BACKFLOW ASSEMBLIES
 PER WPB UTILITIES.
 B) SEPARATE PERMIT IS REQUIRED FOR THE GREASE
 INTERCEPTOR
 C) SEPARATE PERMIT IS REQUIRED FOR GENERATOR AND FUEL
 SYSTEM
 D) SEPARATE PERMIT IS REQUIRED FOR FUEL GAS
 E) KITCHEN IS PERMITTED AS VENILLA SHELL SEPARATE
 PERMIT REQUIRED FOR BUILD OUT OF KITCHEN INCLUDING
 GREASE INTERCEPTOR CALCULATIONS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH