2019-01-16 12:20:14 | THE REFERENCED NUMBERED COMMENTS ARE FROM THE FIRST |
| SUBMITTAL OF SITE PLAN REVIEW, AND INDICATE WHETHER |
| THESE COMMENTS HAVE BEEN ADDRESSED ON THE PLANS |
| SUBMITTED FOR BUILDING PERMIT. NEW COMMENTS HAVE BEEN |
| INCLUDED AT THE END OF THE PREVIOUS COMMENTS. |
| |
| 1. SATISFIED. PLEASE CONSIDER OPEN AIR STRUCTURES UNDER |
| THE HALLWAY AND AREAS CONNECTING TO THE EXISTING |
| STRUCTURE ON THE ROOFTOP TERRACE LEVEL TO MEET THE |
| DISTRICT HEIGHT REQUIREMENTS. |
| 2. SATISFIED. PLEASE PROVIDE MORE DETAIL AND HEIGHT OF |
| THE STRUCTURES ON THE ROOFTOP TERRACE. |
| 3. PARTIALLY SATISFIED. CONSIDER THE USE OF PERMEABLE |
| SURFACE, ESPECIALLY IN THE PROPOSED SURFACE PARKING |
| LOT. |
| PLEASE INDICATE LOCATION OF PERMEABLE SURFACE ON SITE |
| PLAN. |
| 4. SATISFIED. THE COLORED RENDERING AND THE PROPOSED |
| ELEVATIONS DO NOT APPEAR TO MATCH. PLEASE REVISE |
| ACCORDINGLY. |
| 5. SATISFIED. PLEASE NOTE, PER TABLE IV-38, THE CORRECT |
| STREET DESIGNATIONS AND SETBACKS ARE AS FOLLOWS: |
| A. FRONT (8TH STREET): RESIDENTIAL- 17' |
| B. SIDE (9TH STREET): RESIDENTIAL - 17' |
| C. SIDE (HENRIETTA AVE): RESIDENTIAL- 17' |
| D. SIDE (ROSEMARY AVE): SECONDARY - 12' |
| 6. SATISFIED. PLEASE CORRECT THE SITE DATA TABLE, AND |
| INCLUDE THE SETBACK DIMENSIONS OF THE PROPOSED ADDITION |
| AND PARKING LOTS ON THE SITE PLAN (SHEET A0.04, SHEET |
| A1.00). |
| 7. SATISFIED. PLEASE SHOW EXISTING CURBS AND |
| CENTERLINES OF ALL ROADWAYS AND INDICATE WHERE THE |
| CURBS WILL BE MODIFIED. |
| 8. SATISFIED. PLEASE NOTE, IN THE DOWNTOWN MASTER PLAN |
| AREA, SETBACKS ARE MEASURED FROM BACK OF CURB, AS |
| DEFINED IN SECTION 94-109. WHERE THE CURB LOCATION |
| VARIES ALONG A PROPERTY, THE BACK OF CURB SHALL BE |
| DEFINED AS THE PREDOMINANT BACK OF CURB LINE FURTHEST |
| FROM THE CENTER LINE OF THE ROAD (CURB LOCATION ALONG |
| 50% OF STREET FRONTAGE). PLEASE AMEND THE SETBACK |
| MEASUREMENTS AS NECESSARY. |
| 9. SATISFIED. PLEASE NOTE, THE MINIMUM REQUIRED |
| LANDSCAPE BUFFER FOR PARKING CANNOT BE INCLUDED AS PART |
| OF THE REQUIRED SETBACK. PLEASE REVISE ACCORDINGLY. |
| 10. NOT SATISFIED. PLEASE NOTE, THE MAXIMUM BUILDING |
| FOOTPRINT FOR GROUND LEVEL IS 87% AND FOR THE PODIUM IS |
| 90%. PLEASE PROVIDE DETAIL IN THE TABLE ON THE PERCENT |
| BUILDING FOOTPRINT FOR EACH PROPOSED NEW LEVEL. PLEASE |
| AMEND THE LABEL FROM "LOT COVERAGE" TO "BUILDING |
| FOOTPRINT." |
| 11. NOT SATISFIED. PARKING CALCULATIONS IS BASED ON NET |
| INTERIOR AREA, NOT GROSS AREA. PLEASE INCLUDE THE NET |
| INTERIOR AREA AND CALCULATE ACCORDINGLY. PLEASE BREAK |
| DOWN THE TABLE INTO REQUIRED AND PROVIDED PARKING. |
| 12. PARTIALLY SATISFIED. PLEASE SUBMIT AN ILLUSTRATION |
| AND TABLE OF THE F.A.R. BREAKDOWN BY EACH SEPARATE |
| FLOOR, INCLUDING THE ADDITIONAL PARKING. PLEASE |
| SEPARATE THE SQUARE FOOTAGE BY ALLEY, NORTH PROPERTY |
| AND SOUTH PROPERTY. PER SECTION 94-79 (HISTORIC |
| RESIDENTIAL DESIGN STANDARDS), FAR INCLUDES INTERIOR |
| AND ROOFED EXTERIOR STAIRWAYS, ELEVATORS, ESCALATORS |
| AND SIMILAR FEATURES. PLEASE REVISE ACCORDINGLY. |
| 13. NOT SATISFIED. THE APPLICANT SHALL SUBMIT A |
| SEPARATE ALLEY ABANDONMENT APPLICATION. |
| 14. ONGOING. PLEASE NOTE, THE PROPERTIES WILL NEED TO |
| BE UNIFIED. |
| 15. ONGOING. PLEASE NOTE, THIS SITE WILL BE REQUIRED TO |
| BE REPLATTED. |
| 16. SATISFIED. PLEASE INCLUDE ILLUSTRATIONS AND A DATA |
| TABLE DEMONSTRATING COMPLIANCE WITH THE ACTIVE USE |
| REQUIREMENTS FOR NWD-2, AS REQUIRED BY TABLE IV-38. |
| PLEASE NOTE, THE STREET DESIGNATIONS ARE AS FOLLOWS: |
| A. 8TH AVENUE: RESIDENTIAL |
| B. HENRIETTA AVENUE: RESIDENTIAL |
| C. ROSEMARY AVENUE: SECONDARY |
| D. 9TH STREET: RESIDENTIAL |
| 17. SATISFIED. PLEASE INCLUDE ILLUSTRATIONS AND A DATA |
| TABLE DEMONSTRATING COMPLIANCE WITH THE TRANSPARENCY |
| REQUIREMENTS FOR THE GROUND FLOOR IN NWD-2, AS REQUIRED |
| BY TABLE IV-38. PLEASE NOTE, THE STREET DESIGNATIONS |
| ARE AS FOLLOWS: |
| A. 8TH AVENUE: RESIDENTIAL |
| B. HENRIETTA AVENUE: RESIDENTIAL |
| C. ROSEMARY AVENUE: SECONDARY |
| D. 9TH STREET: RESIDENTIAL |
| 18. NOT SATISFIED. THE PROPOSED AISLE WIDTHS IN SOME |
| SECTIONS OF THE PROPOSED PARKING AREAS APPEAR TO BE TOO |
| SMALL. PLEASE LOOK AT SECTION 94-485, FIGURE XV-2 AND |
| REVISE ACCORDINGLY. |
| THE SIZE OF THE TERMINAL ISLAND CAN BE REDUCED TO 5 |
| FEET WITH A MINIMUM RADIUS OF TWO AND ONE-HALF FEET AT |
| ITS END TO MEET THIS REQUIREMENT. |
| 19. SATISFIED. THE PROPOSED NUMBER OF ADA PARKING |
| SPACES DOES NOT MEET THE REQUIREMENT AS ESTABLISHED BY |
| SECTION 94-485, TABLE XV-3. PLEASE REVISE. |
| 20. SATISFIED. IF PROPOSED ADA PARKING SPACES ARE |
| DIAGONAL, THE REQUIRED LENGTH IS 18' AND WIDTH IS 12', |
| PER SECTION 94-485 (O)(2). THE PROPOSED DIAGONAL |
| PARKING SPACE AREA TO THE EAST OF THE BUILDING ADDITION |
| DOES NOT WORK WITH REQUIRED PARKING DEPTHS AND DRIVE |
| AISLE WIDTHS. PLEASE CONSIDER ALTERNATIVES. |
| 21. NOT SATISFIED. THE NUMBER OF ON STREET PARKING |
| ALONG HENRIETTA AVENUE IS LABELED AS 5 SPACES BUT THERE |
| APPEAR TO ONLY BE 4 SPACES. PLEASE CONFIRM LABELS AND |
| TOTAL NUMBERS IN THE SITE DATA TABLE. |
| THE NUMBER OF SPACES IS LABELED AS "3" BUT THERE APPEAR |
| TO BE 4 SPACES. |
| 22. PARTIALLY SATISFIED. THE EXISTING ON SITE POWER |
| POLES APPEAR TO CREATE PROBLEMS WITH PROPOSED |
| SIDEWALKS, ON STREET PARKING AND PROPOSED STREET TREES. |
| PLEASE PROVIDE THE LOCATION OF EXISTING POLES, AND |
| PROVIDE DETAIL OF POLES BEING REMOVED OR NEWLY PROPOSED |
| POLES. PLEASE CONTACT STAFF TO HOLD A SEPARATE MEETING |
| TO DISCUSS THE MULTIPLE ISSUES. |
| THE EXISTING POWER POLES ALONG ROSEMARY AVENUE CREATE |
| AN ACCESSIBILITY ISSUES IN SOME LOCATIONS. THE SIDEWALK |
| NEEDS TO BE ADJUSTED AND EXPANDED AT THESE AREAS TO |
| AVOID ISSUES. THIS IS SHOWN ON SOME PLANS, HOWEVER THE |
| SITE PLAN NEEDS TO SHOW THIS AS WELL. |
| 23. SATISFIED. THE PROPOSED BUS PARKING DOES NOT WORK |
| WITH TURNING RADIUS REQUIREMENTS. PLEASE CONSIDER A BUS |
| PULL-OFF OR OTHER ALTERNATIVE. |
| 24. NOT SATISFIED. THE REQUIRED BICYCLE PARKING FOR |
| COMMERCIAL DEVELOPMENTS IS 1 PER 15 REQUIRED PARKING |
| SPACES WITHIN A SECURED STORAGE AREA. THE REQUIREMENT |
| FOR PUBLIC USE IS ONE SPACE PER EVERY 100 FEET OF |
| STREET FRONTAGE. PLEASE INCLUDE THE DIMENSIONS OF THE |
| STREET FRONTAGES AND DEMONSTRATE COMPLIANCE OF THE |
| SEPARATE BICYCLE PARKING REQUIREMENTS IN THE SITE DATA |
| TABLE. THE BICYCLE PARKING NUMBER IN THE SITE DATA |
| TABLE DOES NOT APPEAR TO MATCH WHAT IS ON THE SITE |
| PLAN. PLEASE UPDATE WITH RESUBMITTAL MEETING THE CITY |
| REQUIREMENTS. |
| 25. SATISFIED. PLEASE REVISE FROM WALL-MOUNTED BIKE |
| RACKS TO GROUND MOUNTED BIKE RACKS ALONG THE NORTH SIDE |
| OF THE BUILDING. |
| 26. NOT SATISFIED. PLEASE INCLUDE BICYCLE RACK DETAIL, |
| MEETING CITY STANDARDS. STAFF WILL PROVIDE DETAIL. |
| PLEASE SHOW EXACT LOCATION OF PROPOSED BICYCLE RACKS |
| AND DIMENSIONS ON THE SITE PLAN. |
| 27. NOT SATISFIED. PLEASE PROVIDE ADDITIONAL |
| FENESTRATION ALONG THE NORTH FACADE OF THE PROPOSED NEW |
| ADDITION, AS IT IS FACING THE PRIMARY PARKING LOT FOR |
| THE BUILDING USE. BLANK WALLS CANNOT BE VISIBLE BY THE |
| GENERAL PUBLIC. BLANK WALL MEANS ANY PORTION OF A |
| FA?ADE THAT HAS AN AREA GREATER THAN 20 PERCENT OF THE |
| ENTIRE FA?ADE ELEVATION THAT IS ABSENT OF FENESTRATION |
| AND IS ABSENT OF A PLANAR BREAK OF AT LEAST TWO FEET IN |
| DEPTH. PLEASE ILLUSTRATE COMPLIANCE WITH BLANK WALL |
| REGULATIONS. |
| 28. NOT SATISFIED. PER SECTION 94-109, TABLE IV-4, ON |
| FACADES ENCLOSING ACTIVE USES (E.G., THE KITCHEN, |
| BATHROOMS), FENESTRATION MUST COVER A MINIMUM OF 15% OF |
| THE FACADE AREA. PLEASE PROVIDE ADDITIONAL FENESTRATION |
| ALONG THE EAST FACADE OF THE PROPOSED BUILDING |
| ADDITION. |
| 29. NOT SATISFIED. PER SECTION 94-109, TABLE IV-4, ON |
| FACADES ENCLOSING NON-ACTIVE USES, ARCHITECTURAL |
| TREATMENT SHALL BE PROVIDED. SEE SECTION 94-109, |
| DEFINITIONS AND MINIMUM REQUIREMENTS FOR ARCHITECTURAL |
| TREATMENT REQUIREMENTS, SPECIFICALLY FOR THE EAST |
| FACADE OF THE PROPOSED ADDITION. PLEASE ADD MORE |
| ARCHITECTURAL TREATMENT TO THE PROPOSED ADDITION. |
| 30. NOT SATISFIED. PER SECTION 94-109, TABLE IV-4, AT |
| THE GROUND FLOOR, HORIZONTAL PROJECTIONS WITH A MINIMUM |
| CUMULATIVE HORIZONTAL LENGTH OF 50% OF THE BUILDING |
| FRONTAGE SHALL BE PROVIDED. IT APPEARS THAT THE |
| FRONTAGES, ESPECIALLY THE NORTH AND EAST ELEVATION MAY |
| NOT MEET THIS REQUIREMENT. PLEASE REVISE AND PROVIDE |
| ILLUSTRATIONS SHOWING THE LENGTH OF HORIZONTAL |
| PROJECTIONS ALONG THE GROUND FLOOR FRONTAGES TO SATISFY |
| THIS REQUIREMENT. |
| 31. NOT SATISFIED. PLEASE PROVIDE DIMENSIONS AND DETAIL |
| OF PROPOSED AWNINGS AND CANOPIES. SEE TABLE IV-5: |
| PROJECTION STANDARDS FOR REGULATIONS. |
| 32. NOT SATISFIED. PLEASE SEE SECTION 94-110(D) FOR |
| SIGNAGE REQUIREMENTS FOR COMMERCIAL AND MIXED-USES |
| WITHIN RESIDENTIAL ENCLAVE PLANNING AREAS. PLEASE |
| PROVIDE DETAIL OF ANY NEWLY PROPOSED SIGNS, AND ADD A |
| NOTE SAYING "SIGNAGE WILL BE REVIEWED SEPARATELY AT |
| TIME OF SIGN PERMITTING" TO THE PLANS. |
| 33. PARTIALLY SATISFIED. PLEASE INCLUDE A SEPARATE OPEN |
| SPACE PLAN AND TABLE MEETING THE REQUIREMENTS OF |
| SECTION 94-109 TABLE IV-6 AND TABLE IV-7. PLEASE NOTE, |
| REQUIRED LANDSCAPE BUFFERS CANNOT BE INCLUDED IN OPEN |
| SPACE CALCULATIONS. |
| PRIVATE OPEN SPACE IS LESS THAN WHAT IS REQUIRED. IN |
| THIS CASE, AS THERE IS NO PUBLIC SPACE REQUIREMENT, THE |
| PLAZA CAN BE COUNTED. ADDITIONALLY, PER SECTION |
| 94-112(B)(1)(C)(3), PROPOSED DEVELOPMENTS WHICH VACATE |
| AN ENTIRE ALLEY WITHIN A BLOCK SHALL PROVIDE AN OPEN |
| SPACE EQUAL TO THE SIZE OF THE VACATED ALLEY AT A RATIO |
| OF 1:1 IN ADDITION TO THE MINIMUM OPEN SPACE |
| REQUIREMENT. CONSIDERING THE CREATION OF THE HEART AND |
| SOUL PARK, STAFF CAN PRESENT THE PARK AS CONSIDERATION |
| FOR THIS REQUIREMENT. PLEASE ILLUSTRATE INTENT OF THIS |
| ON THE OPEN SPACE PLAN WITH INDICATED SQUARE FOOTAGE OF |
| THE ALLEY. |
| 34. SATISFIED. PLEASE CONSIDER AN OPEN SPACE |
| AMENITY/SEATING AREA IN THE REAR OF THE BUILDING FOR |
| KITCHEN STAFF/EMPLOYEES, WHICH COULD THEN BE CONSIDERED |
| IN THE OPEN SPACE CALCULATIONS. |
| 35. PARTIALLY SATISFIED. PLEASE INCLUDE PLANTING ON THE |
| ROOFTOP TERRACE TO PROVIDE A ROOFTOP GARDEN AREA. |
| PLEASE INCLUDE DETAIL OF PROPOSAL AND AMENITIES. |
| PLEASE INCLUDE DETAIL OF ROOFTOP AMENITIES ON HARDSCAPE |
| PLAN. |
| 36. NOT SATISFIED. PER SECTION 94-113(E), CURBS AND |
| WHEEL STOPS, ALL LANDSCAPED AREAS AND PLANT MATERIALS |
| WITHIN OR ADJACENT TO VEHICULAR USE AREAS SHALL BE |
| PROTECTED FROM VEHICULAR ENCROACHMENT BY WHEEL STOPS, |
| CURBS, OR OTHER SIMILAR DEVICES. PLEASE DEMONSTRATE |
| COMPLIANCE. |
| PLEASE USE A D-CURB INSTEAD OF WHEEL STOPS FOR |
| LANDSCAPE PROTECTION. |
| 37. NOT SATISFIED. PER SECTION 94-113(D), STREET |
| LIGHTS, STREET LIGHTING SHALL BE PROVIDED TO ATTAIN THE |
| APPROPRIATE FOOTCANDLE MEASUREMENT NECESSARY FOR SAFE |
| PEDESTRIAN AND VEHICULAR MOVEMENT. LIGHT FIXTURE AND |
| POLES SHALL MEET THE CITY APPROVED STANDARD. PLEASE |
| PROVIDE LOCATION AND DETAIL OF LIGHT FIXTURES. |
| PLEASE SUBMIT PHOTOMETRIC PLANS AND LIGHT FIXTURE |
| DETAILS. |
| 38. SATISFIED. PER SECTION 94-113(D), SIDEWALKS, A |
| SIDEWALK WITH A MINIMUM OF EIGHT FEET CLEAR WIDTH SHALL |
| BE PROVIDED ALONG THE BUILDING FRONTAGE. PLEASE REVISE |
| ACCORDINGLY. |
| 39. SATISFIED. PER SECTION 94-113(F), SURFACE PARKING |
| LOTS SHALL MEET THE MINIMUM GROUND FLOOR SETBACK |
| REQUIREMENTS AS PROVIDED IN THE SUBDISTRICT BUILDING |
| REQUIREMENTS TABLE. A FIVE-FOOT LANDSCAPE BUFFER SHALL |
| BE PROVIDED AROUND THE ENTIRE PERIMETER OF THE SURFACE |
| LOT IN ADDITION TO THE GROUND FLOOR SETBACK TO VISUALLY |
| SCREEN PARKING AREAS. |
| 40. ONGOING. PARKING SHALL COMPLY WITH SECTION |
| 94-113(F) FOR LANDSCAPING REQUIREMENTS. |
| LANDSCAPE REQUIREMENTS SHALL BE REVIEWED THROUGH |
| SEPARATE LANDSCAPE PERMIT. SEE NEW COMMENT #45. |
| 41. PARTIALLY SATISFIED. PLEASE INCLUDE DETAIL AND |
| DIMENSIONS OF THE PROPOSED DUMPSTER ENCLOSURE AREA, |
| MEETING THE REGULATIONS OF SECTION 94-315. |
| PLEASE INCLUDE DETAIL OF TRASH RECEPTACLE ENCLOSURE, |
| INCLUDING MATERIAL AND HEIGHT, MEETING THE |
| SPECIFICATIONS OF SECTION 94-315(A). |
| 42. SATISFIED. CAN VISITORS ENTER THROUGH THE BACK OF |
| THE BUILDING? PLEASE PROVIDE DETAIL INTO BUILDING |
| ENTRANCES FROM EIGHTH STREET AND FROM THE PARKING LOT. |
| PLEASE CONSIDER PEDESTRIAN CONNECTIVITY INCLUDING |
| CROSSWALKS, AND DISTINGUISHED PRIMARY ENTRANCES. |
| 43. SATISFIED. PLEASE CLEAN UP LABELS ON THE PLAN THAT |
| ARE REMAINING FROM THE FIRST SUBMITTAL OR OTHERWISE |
| MISPLACED. |
| 44. SATISFIED. PLEASE REMOVE THE LABEL READING |
| "PROPOSED 3RD FLOOR-PLAN" FROM SHEET A1.03 AND RELABEL |
| AS "PROPOSED ROOFTOP TERRACE" OR SOMETHING SIMILAR. |
| |
| NEW COMMENTS JANUARY 16, 2019 |
| 45. PLEASE NOTE, A SEPARATE LANDSCAPE PLAN WILL BE |
| REQUIRED. |
| 46. PLEASE NOTE, A SEPARATE FENCE PERMIT WILL BE |
| REQUIRED FOR THE PROPOSED METAL FENCE. IN THIS |
| DISTRICT, FENCES SHALL BE A MAXIMUM HEIGHT OF FOUR |
| FEET. PLEASE REVISE HEIGHT ON PLANS. |
| 47. THE LANDSCAPE AND HARDSCAPE PLANS DO NOT MATCH THE |
| NEW BUILDING FOOTPRINT AND ON STREET PARKING SPACE |
| LAYOUT AND HAVE DISCREPANCIES IN PROPOSED LANDSCAPING. |
| PLEASE ADJUST ACCORDINGLY. |
| 48. PLEASE INCLUDE A TREE REMOVAL/RELOCATION PLAN WITH |
| RESUBMITTAL. |
| 49. ARE GATES PROPOSED TO ACCESS THE PARKING LOT? |
| PLEASE NOTE, A QUEUING DISTANCE OF AT LEAST 20 FEET IS |
| REQUIRED PER SECTION 94-111(P). |
| 50. PLEASE SHOW ANY ABOVE GROUND UTILITIES, |
| TRANSFORMERS, BACKFLOW PREVENTERS, ETC. ON THE SITE |
| PLAN. THESE SHALL NOT BE LOCATED WITHIN THE MINIMUM |
| SETBACK. |
| 51. PLEASE ENLARGE THE INTERNAL SIDEWALK WITHIN THE |
| PLAZA THAT LEADS FROM THE ADA PARKING TO THE 8TH STREET |
| ENTRANCE TO ALLOW FOR BETTER PEDESTRIAN ACCESS. |
| 52. PLEASE ADD SIDEWALK AND SETBACK DIMENSIONS ON THE |
| HARDSCAPE PLAN SHEET HP-1. |
| 53. THE PROPOSED LOCATION OF THE WALL/FENCE ON THE |
| HARDSCAPE PLAN DOES NOT MATCH THE PROPOSED LOCATION ON |
| THE LANDSCAPE PLAN. PLEASE CLARIFY AND REVISE |
| ACCORDINGLY. |
| 54. THIS PROJECT HAS NOT RECEIVED SITE PLAN APPROVAL. |
| PLEASE SUBMIT FOR SITE PLAN APPROVAL BEFORE BUILDING |
| PERMIT CAN BE REVIEWED FURTHER. |
| |
| LIZ LEVESQUE, URBAN DESIGN PLANNER |