Plan Review Notes For Permit 18110074 |
Permit Number |
18110074 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2019-01-02 14:28:53 | 01/02/2019 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. THERE IS A FUTURE KITCHEN AND NO PLUMBING IS SHOWN | | ON PLANS P ME.1. SHOW THE LAYOUT OF THE KITCHEN AND AN | | ISOMETRIC DIAGRAM OF THE SANITARY SYSTEM. SHOW | | CONNECTION TO EXISTING PLUMBING AND HOW WATER IS | | CONNECTED. | | 2. PLUMBING RISER DIAGRAM REQUIRED WPB AMENDMENTS TO | | THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|