2019-02-05 09:48:58RESIDENTIAL (R3) SHUTTERS BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- REVISE INSTALLATION. ACCORDING TO INSTALLATION
 SCHEDULE ON SHEET 12 OF 20 THE ANCHOR SPACING FOR
 TAPCONS IS LESS THAN 10" FOR SHUTTERS THAT HAVE A SPAN
 GREATER THAN 72". REVISE AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 2- REVISE INSTALLATION SCHEDULE. THE SHUTTER SPAN IS
 INCORRECT. THE SHUTTER SPAN IS THE LENGTH OF THE
 SHUTTER. SEE TYPICAL SHUTTER ELEVATION ON SHEET 5 OF 20
 AND REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  