2019-01-10 08:56:25 | NEW SINGLE FAMILY RESIDENCE (R3), THIRD BUILDING REVIEW |
| CHECKLIST. |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| NOTE: |
| BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| ISSUANCE. |
| |
| |
| 1-OK. PROVISO. LOT DRAINAGE TO BE VERIFIED FOR FINAL |
| INSPECTION. |
| |
| 2-LOT SPLIT. ADDRESSING NEED TO BE COORDINATED BEFORE |
| ISSUANCE OF PERMIT. |
| |
| 3- AREAS CORRECTED. VALUATION WAS UPDATED TO $608,478 |
| AS REQUIRED BY SEC. 109.3 CITY AMENDMENTS. . THE PERMIT |
| FEE BALANCE IS $10,479.41. |
| |
| 4- OK. |
| |
| 5- OK. |
| |
| 6- SPECIFY ATTIC ACCESS SIZE AND LOCATION. SEC. R307.1 |
| FBC-RESIDENTIAL. PROVISO: CHECK FOR READILY ACCESSIBLE |
| LOCATION. . |
| |
| 7- STAIRWAY WINDOW SYSTEM BY STAIRWAY: |
| A) SHEET A-003 SPECIFIES "STAIRWAY WINDOW SYSTEM DETAIL |
| (BY OTHER)". PROVIDE COMPLETE INFORMATION AS A DEFERRED |
| SUBMITTAL (NO FEES). SEC. R301.1 FBC-RESIDENTIAL. |
| WINDOW SYSTEM TO BE REVIEWED/APPROVED BY ARCHITECT |
| PRIOR TO SUBMITTAL. |
| |
| B) ARCHITECT TO PROVIDE COMPLETE DETAIL AND |
| SPECIFICATIONS FOR WALL FRAMING AT STAIRWAY SUPPORTING |
| THE WINDOW SYSTEM. SEC. R301.1 FBC-RESIDENTIAL. |
| |
| 8- OK. |
| |
| ORIGINAL COMMENT: |
| 9- WINDOWS AND DOORS DESIGN PRESSURES SHOWN ON THE |
| EXTERIOR ELEVATIONS SEEM TO BE LOW FOR A TWO STORY |
| BUILDING LOCATED IN EXPOSURE "C" AND A WIND SPEED OF |
| 175MPH AS SPECIFIED ON PLANS. . ALSO, SOME WINDOWS ARE |
| LOCATED IN END ZONE NOT INTERIOR (SEE NOTE "A" ON |
| FIGURE R301.2(7) FOR MIN. END ZONE DIMENSION). REVISE |
| AS REQUIRED, INCLUDING THE GARAGE DOORS. SEC. R301.2.1 |
| FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| ENGINEER LETTER FROM WILLIAM F. STUHRKE, PHD, PE IS |
| INCORRECT: |
| (A) BUILDING EXPOSURE WAS CHANGED FORM EXPOSURE C TO |
| EXPOSURE B. THIS SEEMS TO BE INCORRECT. ACCORDING TO |
| SEC. R301.2.1.4 AND SEC. R301.2.1.4.1 THIS BUILDING IS |
| LOCATED IN EXPOSURE C NOT B. REVISE INFORMATION IN ALL |
| PLANS AS REQUIRED OR PROVIDE COMPLETE ENGINEER ANALYSIS |
| FOR EACH WIND DIRECTION. SEC. 107.2.1.2 CITY |
| AMENDMENTS. |
| |
| (B)CLARIFY IF DESIGN PRESSURES SHOWN ON THE EXTERIOR |
| ELEVATIONS ARE GIVEN AS ULTIMATE WIND SPEED OR NOMINAL |
| WIND SPEED. SEC. R301.2.1.3 FBC-RESIDENTIAL. |
| |
| (C)THE ADDRESS IS INCORRECT. |
| |
| (D)ENGINEER STATES THAT THERE ARE NO WINDOWS LOCATED IN |
| ZONE 5. THIS IS INCORRECT. THERE ARE SOME WINDOWS THAT |
| ARE LOCATED WITHIN 4 FEET OF THE CORNER. REVISE ALL |
| RELEVANT INFORMATION AS REQUIRED. |
| |
| (E)NEED ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS |
| REQUIRED BY F. S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC |
| RECORDS. NOTE: THIS IS NOT A DIGITAL SUBMITTAL. HARD |
| COPIES ARE REQUIRED. |
| |
| ORIGINAL COMMENT: |
| 10- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| INSTALLATION OF THE STONE VENEER SHOWN ON THE EXTERIOR |
| ELEVATIONS TO SHOW COMPLIANCE WITH THE WIND RESISTANCE |
| SEC. R703.1.2 FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| REVISE BATHROOM BUMP METAL FRAMING ENCLOSURE DETAIL ON |
| SHEET A-010. THIS DETAIL SPECIFIES STUCCO. REVISE TO |
| MATH PROPOSED STONE VENEER. SEC. R301.1 |
| FBC-RESIDENTIAL. |
| |
| ORIGINAL COMMENT: |
| 11- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| BALCONY FLOOR CONSTRUCTION. ALSO SPECIFY WATERPROOFING |
| AND FINISH FLOOR. SEC. R301.1 FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| BALCONY FLOOR CONSTRUCTION DETAIL ON SHEET A-010 |
| DOESN'T SPECIFY FINISH FLOOR. COORDINATE WITH SELECTED |
| ASSEMBLY W-4 FROM FLORIDA PRODUCT APPROVAL FL16709-R4 |
| SUBMITTED. |
| |
| 12-OK. |
| |
| 13- OK. |
| |
| 14- OK. |
| |
| 15- OK. |
| |
| |
| 16- OK. |
| |
| 17- OK. |
| |
| 18- OK. |
| |
| 19- SHEET 004: |
| A) OK. |
| B) OK. |
| C) OK. |
| |
| 20- OK. |
| |
| 21- OK. |
| |
| 22- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| FAC 61G20-3.001 FOR: |
| (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| SUBMITTAL) |
| |
| A) OK. |
| B) BALCONY UNDERLAYMENT THAT IS DESIGNED TO BE |
| INSTALLED WITH FINISH FLOOR SPECIFIED ON PLANS. |
| DESIGNER OF RECORD TO PROVIDE SPECIFICATIONS FOR FINISH |
| FLOORING. NOTE: CLEARLY IDENTIFY SPECIFIC ASSEMBLY TO |
| BE INSTALLED AND RAS 117 CALCULATIONS MAY BE REQUIRED |
| IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES |
| FOR ALL ZONES. |
| NOTE: THIS NEEDS TO BE COORDINATED WITH ITEM #11 ABOVE. |
| |
| C) OK. |
| |
| NOTE: PRODUCT APPROVALS WILL BE REVIEWED ONCE BUILDING |
| EXPOSURE AND DESIGN PRESSURES ARE REVISED. SEE ITEM #9 |
| ABOVE. |
| |
| D) SLIDING GLASS DOORS WITH TRANSOM ABOVE AS SHOWN ON |
| PLANS/ELEVATIONS. |
| |
| E) CASEMENT WINDOWS SIZE AS SPECIFIED ON WINDOW |
| SCHEDULE. SEE PLANS/ELEVATIONS. |
| |
| F) INSWING ENTRY DOORS WITH SIDELITES AND TRANSOM ABOVE |
| AS SHOWN ON PLANS/ELEVATIONS. |
| NOTE: NOA 18-0503.06 SUBMITTED IS FOR OUTSWING ENTRY |
| DOORS ONLY. |
| |
| G)WINDOW MULLIONS AS SHOWN ON PLANS. REQUIRED: CLEARLY |
| SPECIFY MULLION SIZE TO BE USED TO VERIFY COMPLIANCE |
| WITH THE CALCULATED DESIGN PRESSURES. |
| |
| H)WINDOW SYSTEM SHOWN BY THE STAIRWAY. |
| |
| 23- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| 24- ENERGY CALCULATIONS SUBMITTED (RESCHECK): |
| A) LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND |
| SHGC FACTOR IS REQUIRED. |
| B) BLOWER DOOR TEST WILL BE REQUIRED. |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE |
| PREVIOUSLY REVIEWED SHEETS. |
| PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| FOR REFERENCE. |
| |
| |