Plan Review Notes
Plan Review Notes For Permit 18100671
Permit Number 18100671
Review Stop B
Sequence Number 2
Notes
Date Text
2019-01-03 17:33:13NEW SINGLE FAMILY RESIDENCE (R3), SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
  
 1-OK. PROVISO. LOT DRAINAGE TO BE VERIFIED FOR FINAL
 INSPECTION.
  
 2-LOT SPLIT. ADDRESSING NEED TO BE COORDINATED BEFORE
 ISSUANCE OF PERMIT.
  
 3- AREAS CORRECTED. VALUATION WAS UPDATED TO $608,478
 AS REQUIRED BY SEC. 109.3 CITY AMENDMENTS. . THE PERMIT
 FEE BALANCE IS $10,479.41.
  
 4- OK.
  
 5- OK.
  
 6- SPECIFY ATTIC ACCESS SIZE AND LOCATION. SEC. R307.1
 FBC-RESIDENTIAL. PROVISO: CHECK FOR READILY ACCESSIBLE
 LOCATION. .
  
 7- SEMI COMPLIED. PROVIDE COMPLETE INFORMATION FOR
 STAIRWAY WINDOW SYSTEM.
  
 8- OK.
  
 ORIGINAL COMMENT:
 9- WINDOWS AND DOORS DESIGN PRESSURES SHOWN ON THE
 EXTERIOR ELEVATIONS SEEM TO BE LOW FOR A TWO STORY
 BUILDING LOCATED IN EXPOSURE "C" AND A WIND SPEED OF
 175MPH AS SPECIFIED ON PLANS. . ALSO, SOME WINDOWS ARE
 LOCATED IN END ZONE NOT INTERIOR (SEE NOTE "A" ON
 FIGURE R301.2(7) FOR MIN. END ZONE DIMENSION). REVISE
 AS REQUIRED, INCLUDING THE GARAGE DOORS. SEC. R301.2.1
 FBCD-RESIDENTIAL.
  
 RESPONSE:
 ENGINEER LETTER FROM WILLIAM F. STUHRKE, PHD, PE IS
 INCORRECT:
 (A) BUILDING EXPOSURE WAS CHANGED FORM EXPOSURE C TO
 EXPOSURE B. THIS SEEMS TO BE INCORRECT. ACCORDING TO
 SEC. R301.2.1.4 AND SEC. R301.2.1.4.1 THIS BUILDING IS
 LOCATED IN EXPOSURE C NOT B. REVISE INFORMATION IN ALL
 PLANS AS REQUIRED OR PROVIDE COMPLETE ENGINEER ANALYSIS
 FOR EACH WIND DIRECTION. SEC. 107.2.1.2 CITY
 AMENDMENTS.
  
 (B)CLARIFY IF DESIGN PRESSURES SHOWN ON THE EXTERIOR
 ELEVATIONS ARE GIVEN AS ULTIMATE WIND SPEED OR NOMINAL
 WIND SPEED. SEC. R301.2.1.3 FBC-RESIDENTIAL.
  
 (C)THE ADDRESS IS INCORRECT.
  
 (D)ENGINEER STATES THAT THERE ARE NO WINDOWS LOCATED IN
 ZONE 5. THIS IS INCORRECT. THERE ARE SOME WINDOWS THAT
 ARE LOCATED WITHIN 4 FEET OF THE CORNER. REVISE ALL
 RELEVANT INFORMATION AS REQUIRED.
  
 (E)NEED ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS
 REQUIRED BY F. S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC
 RECORDS. NOTE: THIS IS NOT A DIGITAL SUBMITTAL. HARD
 COPIES ARE REQUIRED.
  
 ORIGINAL COMMENT:
 10- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 INSTALLATION OF THE STONE VENEER SHOWN ON THE EXTERIOR
 ELEVATIONS TO SHOW COMPLIANCE WITH THE WIND RESISTANCE
 SEC. R703.1.2 FBC-RESIDENTIAL.
  
 RESPONSE:
 REVISE BATHROOM BUMP METAL FRAMING ENCLOSURE DETAIL ON
 SHEET A-010. THIS DETAIL SPECIFIES STUCCO. REVISE TO
 MATH PROPOSED STONE VENEER. SEC. R301.1
 FBC-RESIDENTIAL.
  
 ORIGINAL COMMENT:
 11- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 BALCONY FLOOR CONSTRUCTION. ALSO SPECIFY WATERPROOFING
 AND FINISH FLOOR. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 BALCONY FLOOR CONSTRUCTION DETAIL ON SHEET A-010
 DOESN'T SPECIFY FINISH FLOOR. COORDINATE WITH SELECTED
 ASSEMBLY W-4 FROM FLORIDA PRODUCT APPROVAL FL16709-R4
 SUBMITTED.
  
 12-OK.
  
 13- OK.
  
 14- OK.
  
 15- OK.
  
  
 16- OK.
  
 17- OK.
  
 18- OK.
  
 19- SHEET 004:
 A) OK.
 B) OK.
 C) OK.
  
 20- OK.
  
 21- OK.
  
 22- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) OK.
 B) BALCONY UNDERLAYMENT THAT IS DESIGNED TO BE
 INSTALLED WITH FINISH FLOOR SPECIFIED ON PLANS.
 DESIGNER OF RECORD TO PROVIDE SPECIFICATIONS FOR FINISH
 FLOORING. NOTE: CLEARLY IDENTIFY SPECIFIC ASSEMBLY TO
 BE INSTALLED AND RAS 117 CALCULATIONS MAY BE REQUIRED
 IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES
 FOR ALL ZONES.
 NOTE: THIS NEEDS TO BE COORDINATED WITH ITEM #11 ABOVE.
  
 C) OK.
  
 NOTE: PRODUCT APPROVALS WILL BE REVIEWED ONCE BUILDING
 EXPOSURE AND DESIGN PRESSURES ARE REVISED. SEE ITEM #9
 ABOVE.
  
 D) SLIDING GLASS DOORS WITH TRANSOM ABOVE AS SHOWN ON
 PLANS/ELEVATIONS.
  
 E) CASEMENT WINDOWS SIZE AS SPECIFIED ON WINDOW
 SCHEDULE. SEE PLANS/ELEVATIONS.
  
 F) INSWING ENTRY DOORS WITH SIDELITES AND TRANSOM ABOVE
 AS SHOWN ON PLANS/ELEVATIONS.
 NOTE: NOA 18-0503.06 SUBMITTED IS FOR OUTSWING ENTRY
 DOORS ONLY.
  
 G)WINDOW MULLIONS AS SHOWN ON PLANS. REQUIRED: CLEARLY
 SPECIFY MULLION SIZE TO BE USED TO VERIFY COMPLIANCE
 WITH THE CALCULATED DESIGN PRESSURES.
  
 H)WINDOW SYSTEM SHOWN BY THE STAIRWAY.
  
 23- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 24- ENERGY CALCULATIONS SUBMITTED (RESCHECK):
 A) LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND
 SHGC FACTOR IS REQUIRED.
 B) BLOWER DOOR TEST WILL BE REQUIRED.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
  