Date |
Text |
2018-10-24 12:56:50 | BUILDING REVIEW COMMENTS |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| 1- THE PROPOSED WORK IS OUTSIDE THE LICENSING SCOPE OF |
| A FENCE CONTRACTOR. THIS IS NOT A FENCE. SEE BELOW FOR |
| COPY OF FENCE CONTRACTOR SCOPE OF WORK. THIS IS A |
| STRUCTURAL HANDRAIL AND GUARDRAIL. NEED CONTRACTOR THAT |
| CAN BUILD THE PROPOSED SCOPE OF WORK. |
| |
| CONSTRUCTION INDUSTRY LICENSING BOARD |
| OF PALM BEACH COUNTY |
| STANDARDS FOR CERTIFIED CATEGORIES |
| PER CHAPTER 67-1876, SPECIAL ACT, |
| LAWS OF FLORIDA, AS AMENDED (REV. 10/30/17) |
| |
| FENCE CONTRACTORS ARE THOSE WHO ARE QUALIFIED TO |
| CONSTRUCT, INSTALL, MAINTAIN, ALTER, EXTEND OR REPAIR |
| FENCING, INCLUDING WOOD, PRE-CAST CONCRETE, |
| PRE-FABRICATED FENCES CHILD PROOF BARRIER (KIDDIES) |
| FENCES FOR POOLS, MECHANICAL SWIMMING POOL COVERS AND |
| GATES, IN COMPLIANCE WITH SAFETY, ZONING AND BUILDING |
| CODES. ELECTRICAL INSTALLATION MAY BE INCLUDED IN THE |
| CONTRACT FOR WORK, BUT MUST BE SUBCONTRACTED TO A |
| CERTIFIED ELECTRICAL CONTRACTOR. (REV. |
| |
| U-21309 ACTIVE SHEA, MITCHELL JEREMY BULLDOG FENCE OF |
| FLORIDA LLC FENCE CONTRACTOR |
| |
| |
| 2- ENGINEERED DRAWINGS SUBMITTED: |
| A) ENGINEER'S DRAWINGS SUBMITTED NEED TO HAVE THE |
| ENGINEER'S COMPLETE INFORMATION AND NEED ENGINEER'S |
| ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471 |
| FLORIDA STATUTE. |
| |
| B) NOTES ON THE ENGINEERED DRAWINGS SUBMITTED SEEM TO |
| APPLY TO FENCES NOT HANDRAILS AND GUARDRAILS. PROVIDE |
| CORRECT INFORMATION THAT APPLIES TO PROPOSED WORK. SEE |
| SEC. SEC. 1607.8 FBC. |
| |
| C) PROPOSED WORK IS NOT CLEAR. PROVIDE COMPLETE |
| DRAWINGS THAT ARE SPECIFIC FOR THE ELEVATED AREA. |
| SPECIFY ALL DIMENSIONS, SLOPES, HANDRAIL AND GUARDRAIL |
| INFORMATION. NOTE: PROVIDE THE PERMIT NUMBER WHEN THE |
| ELEVATED AREA WAS BUILT. THIS WILL FACILITATE THE |
| REVIEW. ADDITIONAL DRAWINGS MAY NOT BE REQUIRED IF THIS |
| WORK WAS ALREADY APPROVED. OTHERWISE, PLANS NEED TO BE |
| REVIEWED FOR THE COMPLETE SCOPE OF WORK: ELEVATED AREA |
| AND GUARDRAIL/ HANDRAIL WORK. SEC. 107.2.1 CITY |
| AMENDMENTS. |
| |
| |
| |
| ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| |
| ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY |
| REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |