2018-10-15 13:32:02 | ****CORRECTIONS**** | | W.P.B. PERMIT: 18100288 | | REVIEWED: OCTOBER 15, 2018 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER I | | [email protected] | | 561-805-6718 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC ENERGY = FBC ENERGY CONSERVATION | | | | 1. [FBC 1017]MAXIMUM COMMON PATH OF EGRESS TRAVEL | | DISTANCE SHEET G110. PLEASE LABEL THE FARTHEST POINT | | UNTIL CHOICE OF 2 EXITS AS COMMON PATH OF TRAVEL AND | | THEN LABEL THE PART AFTER AS THE TOTAL TRAVEL DISTANCE. | | ALSO, SHOW CHOICE OF TWO EXITS AT CIRCULATION 322 NEAR | | RECEPTION WHERE YOU CAN GO TO STAIR 1 OR STAIR 3. | | | | 2. [FBC 107.2.5]SHEET A300 REMOVE NOTE IN FLOOR FINISH | | GENERAL NOTES ABOUT WALK-IN COOLER. | | | | 3. [FBC 107.2.5]ADD DIMENSIONS WHERE NEW WALLS ARE | | BEING INSTALLED. FOR INSTANCE DEPTH OF ROOMS 304, 303, | | 307, 308, 309 AND 310. PLEASE REVIEW FOR ANY ADDITIONAL | | DIMENSIONS THAT WOULD BE USED FOR NEW WALLS AND | | OPENINGS. | | | | 4. [FBC A604.3]315EX UNISEX ADA LAV. SHOW CLEARANCE | | AROUND WATER CLOSET. | | | | 5. [FBC A602.2]SHOW ADA CLEARANCE AT WATER FOUNTAINS. | | | | |
|