Plan Review Notes
Plan Review Notes For Permit 18090633
Permit Number 18090633
Review Stop P
Sequence Number 1
Notes
Date Text
2018-10-18 13:45:55CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW:
 PLUMBING COMMENTS: DENIED
  
 1. WPB FBC 107.3.5.3(12): PROVIDE SANITARY RISER
 DIAGRAM SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR
 THE DESIGN IN ACCORDANCE WITH FS 471 & 481.; SHOW HOW
 THE NEW SANITARY PIPING WILL INTEGRATE WITH EXISTING
 SYSTEM SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR
 THE DESIGN IN ACCORDANCE WITH FS 471 & 481. CLOUD NEW
 WORK. SHOW ALL REQUIRED DRAINS,TRAPS AND VENTS AND SIZE
 IN ACCORDANCE WITH FBC RES INCLUDING BUT NOT LIMITED
 TO, CHAPTERS 30, 31 AND 32 .
 2. WPB FBC 107.2.1: PLAN A-102 SHOWS RELOCATED WASHER,
 DRYER AND WATER HEATER OUT SIDE OF MAIN STRUCTURE IN AN
 AREA THAT MAY PROVIDE AN OVERHANG AND NO EXTERIOR
 WALLS; PLEASE CLARIFY. PROVIDE MANUFACTURER'S
 DOCUMENTATION ALLOWING APPLIANCES TO BE INSTALLED IN A
 WET AREA.
 3. FBC RES P2708.4: TUB/SHOWER CONTROL VALVE(S) SHALL
 BE PRESSURE BALANCED PB, THERMOSTATIC MIXING (TM) OR
 COMBINATION PB/TM VALVE TYPES WITH HIGH TEMPERATURE
 LIMITING STOP.
 4. FBC RES P2903.5: PROVIDE WATER HAMMER ARRESTORS AT
 WATER SUPPLIES TO ICE LINE, DISHWASHER AND CLOTHES
 WASHER.
 5. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE DETAILED, QUANTITY ESTIMATES, AND/OR BONA
 FIDE SIGNED CONTRACTS WITH SCOPE AND VALUE OF WORK, TO
 INCLUDE ALL MATERIALS AND LABOR. THIS IS FOR TOTAL
 PROJECT, NOT JUST PLUMBING. WPB FBC 109.3
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN
 ACCORDANCE WITH FS 471, 481 & FAC 61G15) INTO THE
 ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED
 SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS
 SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved