Plan Review Notes For Permit 18090449 |
Permit Number |
18090449 |
|
Review Stop |
E |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2018-10-01 10:56:54 | PLAN PASSED WITH PROVISIONS: | | | | AS PER FBC EB 808.1 FOR A LEVEL 2 ALTERATION | | | | KITCHEN LIGHTING TO BE AFCI PROTECTED AS PER 210.12A&B | | NEC | | | | EXHAUST FAN IN KITCHEN TO BE AFCI PROTECTED AS PER | | 210.12 NEC | | | | ALL RECEPTACLES BOTH NEW AND REPLACED TO BE AFCI/GFCI | | PROTECTED IN KITCHEN THAT SERVE COUNTERTOPS 210.8A#6 & | | 210.12A | | | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | | | | | | | |
|