2018-09-18 16:47:54 | |
| |
| *****NOTE: |
| PER ROBERT BROWN. NEED SUBPERMIT FOR ROOF TO WALL |
| CONNECTIONS. RESPONDED E-MAIL TO CONTRACTOR. |
| |
| RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| 1- 1- HOUSE VALUE IS MORE THAN $300.000. NEED TO COMPLY |
| WITH THE ROOF TO WALL CONNECTIONS AS REQUIRED BY SEC. |
| 706.8 FBC-EXISTING-BUILDING. |
| |
| SEC. 706.8: |
| WHEN A ROOF COVERING ON AN EXISTING SITE-BUILT SINGLE |
| FAMILY RESIDENTIAL STRUCTURE IS REMOVED AND REPLACED ON |
| A BUILDING THAT IS LOCATED IN THE WIND-BORNE DEBRIS |
| REGION AS DEFINED IN THE FLORIDA BUILDING CODE, |
| BUILDING AND THAT HAS AN INSURED VALUE OF $300,000 OR |
| MORE OR, IF THE BUILDING IS UNINSURED OR FOR WHICH |
| DOCUMENTATION OF INSURED VALUE IS NOT PRESENTED, HAS A |
| JUST VALUATION FOR THE STRUCTURE FOR PURPOSES OF AD |
| VALOREM TAXATION OF $300,000 OR MORE: |
| (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS |
| REQUIRED BY SECTION 706.8.1. |
| (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION |
| SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN |
| THE COST OF REROOFING. |
| EXCEPTION: SINGLE-FAMILY RESIDENTIAL STRUCTURES |
| PERMITTED SUBJECT TO THE FLORIDA BUILDING CODE ARE NOT |
| REQUIRED TO COMPLY WITH THIS SECTION. |
| |
| |
| 2- CLEARLY MARK THE ADHESIVE PADDY SIZE ON ROOF TILE |
| AND ON ADHESIVE PRODUCT APPROVAL SUBMITTED AS REQUIRED |
| BY CITY POLICY FOR ROOFING PERMITS TO VERIFY COMPLIANCE |
| WITH PROPOSED INSTALLATION. SEC. 107.2.1 CITY |
| AMENDMENTS. |
| |
| 3- BORAL TILESEAL ROOFING UNDERLAYMENT NOA 17-0530.10 |
| SUBMITTED EXPIRED ON 07/31/18. PROVIDE CURRENT NOA. |
| FAC 61G20.3.001 |
| |
| |
| |