Plan Review Notes
Plan Review Notes For Permit 18090327
Permit Number 18090327
Review Stop B
Sequence Number 2
Notes
Date Text
2018-12-18 15:54:39NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
  
 1-IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]
  
 2- PROVIDE DRAINAGE PLAN.
 A) CIVIL DRAWINGS C1 AND C2 ARE MISSING THE DIGITAL
 SIGNATURE. CHAPTER 471 F.S.
  
 B) CIVIL DRAWINGS ARE SHOWING THE ELEVATIONS BASED ON
 NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD'29).
 ENGINEER TO USE THE NORTH AMERICAN VERTICAL DATUM OF
 1988 (NAVD'88) AS USED IN SURVEY PROVIDED TO AVOID
 CONFLICTS/CONFUSION/DELAYS DURING CONSTRUCTION. SEC.
 107.2.1 CITY AMENDMENTS.
  
 3- OK
  
 4- SURVEY:
 A)OK
 B)OK
 C)NEED TO PROVIDE HARD COPY OF SURVEY WITH ORIGINAL
 SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 472 F. S. OR
 SUBMIT SURVEY DIGITALLY SIGNED.
  
 NEW COMMENT:
 D)PROPOSED LOT DRAINAGE DOESN'T WORK AND DOESN'T MATCH
 DRAINAGE PLANS SUBMITTED BY ENGINEER. DELETE DRAINAGE
 INFORMATION OR MATCH CIVIL DRAWINGS TO AVOID
 CONFLICTS/CONFUSION/DELAYS DURING CONSTRUCTION. SEC.
 107.2.1 CITY AMENDMENTS.
  
 5- SECOND FLOOR EGRESS WINDOWS: SPECIFIED WINDOW SIZE
 MAY OR MAY NOT COMPLY DEPENDING ON THE WINDOW
 MANUFACTURER. PROVIDE PROVIDE MANUFACTURER'S CUT SHEETS
 SHOWING THAT WINDOW W11 COMPLIES WITH THE CLEAR AND
 TOTAL CLEAR OPENING REQUIRED BY SEC. R310.2.1
 FBC-RESIDENTIAL. (TO BE FIELD VERIFIED)
  
 6- A)OK.
  
 B) OK
  
 7- OK
  
 8- OK
  
 9- PROVIDE DETAILS AND SPECIFICATIONS FOR STRUCTURAL
 BUCK DETAILS SHOWING COMPLIANCE WITH SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 10- CLARIFY WOOD BEAM TO WOOD POST CONCEALED CONNECTOR
 SPECIFIED ON DETAIL 3 AND 4 ON SHEET S-3.02. SIMPSON
 CBT2Z IS FOR 4X4 POST NOT FOR 8X8 POST. CLARIFY/REVISE
 AS REQUIRED. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 DETAIL 3 WAS REVISED BUT DETAIL 4 WAS NOT.
  
 NOTE: SEQUENCE OF STRUCTURAL DRAWINGS DON'T MATCH
 DRAWING NUMBER SHOWN ON THE UPLOADED DRAWING
 TITLE.PLEASE COORDINATE.
  
 11- A)OK.
  
 B) OK
  
 12- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR WINDOWS IN THE DORMER AREA. SPECIFY ALL FRAMING
 MEMBERS AND CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL.
  
 13- PROVIDE DETAILS AND SPECIFICATIONS FOR THE
 INSTALLATION OF THE CEDAR SHUTTERS SHOWN ON PLANS. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 14- OK
  
 15- OK.
  
 16- OK
  
 17- SOIL TEST REPORT: NEED TO PROVIDE HARD COPY OF SOIL
 TEST REPORT WITH ORIGINAL SEAL AND SIGNATURE AS
 REQUIRED BY CHAPTER 471 F. S.
  
 18- PROVIDE ICC EVALUATION REPORT FOR "POLYISO SPRAY
 FOAM" SPECIFIED ON PLANS TO SHOW COMPLIANCE WITH SEC.
 R316 FBC-RESIDENTIAL.
 NOTE: ICC REPORT TO BE REVIEWED AND APPROVED BY THE
 ARCHITECT OF RECORD PRIOR TO SUBMITTAL TO THIS OFFICE.
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 19- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: PER RESPONSE LETTER, THIS WILL BE SUBMITTED
 LATER AS A DEFERRED SUBMITTAL) (NO FEE FOR DEFERRED
 SUBMITTALS. )
  
 NOTE: COORDINATE ALL SUPPORTING DOCUMENTS LABELS AND
 INFORMATION SUBMITTED. FOR EXAMPLE "SOIL
 REPORT-REV.PDF" AND INFORMATION THAT WAS UPLOADED DON'T
 MATCH.
  
 A) PRECAST LINTELS
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR OR DESIGN PROFESSIONAL TO LIST THE FLORIDA
 PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED
 CONNECTOR.
  
 C)HARDIE PLANK LAP SIDING AND CEMENT BOARD TRIM AS
 SHOWN ON ELEVATIONS.
  
 D) WINDOW MULLIONS AS SHOWN ON PLANS. REQUIRED: CLEARLY
 SPECIFY MULLION SIZE TO BE USED TO VERIFY COMPLIANCE
 WITH THE CALCULATED DESIGN PRESSURES.
  
 E) NOTE: PROVIDE THE FLORIDA PRODUCT APPROVAL COVER
 PAGES THAT CORRESPOND TO DRAWINGS SUBMITTED FOR THE
 ENTRY DOOR, GARAGE SIDE DOOR, KITCHEN DOOR AND FRENCH
 DOORS SHOWN ON PLANS.
  
 20-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
 NOTE: DESIGNER OF RECORD TO PROVIDE REVIEW APPROVAL ON
 COVER PAGE OF PRODUCT APPROVAL OR SEPARATE REVIEW
 LETTER CLEARLY IDENTIFYING EACH SPECIFIC PRODUCT. FOR
 EXAMPLE PGT SINGLE HUNG SH-700 NOA 17-0630.08.
  
 21-REVISE ENERGY CALCULATIONS. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION. COORDINATE WITH ARCHITECT TO
 AVOID CONFLICTS/DELAYS.
 A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER'S NAME, BUILDER'S NAME, PERMIT OFFICE,
 ETC.
  
 B) A/C AREA SHOWN ON ITEM #6 DOESN'T MATCH PLANS.
  
 C) INSULATION ON SLAB ON GRADE AND FLOOR OVER OTHER
 SPACE ON ITEM #8 DOESN'T MATCH PLANS.
  
 D) R VALUE INSULATION ON EXTERIOR AND INTERIOR WALLS
 DON'T MATCH PLANS. NOTE: ALSO NOTE THAT ADJACENT WALL
 IS PARTIAL METAL FRAMING AND PARTIAL MASONRY. SEE
 PLANS.
  
 E)CLARIFY NUMBER OF PEOPLE SPECIFIED ON PAGE 2 OF 5.
 HOW MAY PEOPLE ARE IN THE 3 BEDROOM HOUSE. EIGHT
 PEOPLE?. 4 UPSTAIRS AND 4 DOWNSTAIRS?. TYPICALLY, THE
 NUMBER OF PEOPLE IS TAKEN BASED ON THE NUMBER OF
 BEDROOMS.
 IT LOOKS LIKE COUNTING THE PEOPLE TWICE. WHY?
  
 F) CLARIFY WHERE IS THE 6 FEET BY 7 FEET WOOD DOOR
 SPECIFIED ON PAGE OF 5. COORDINATE WITH PLANS AND
 PRODUCT APPROVALS SUBMITTED.
  
 G)WINDOWS AND DOORS WITH GLAZING ARE NOT VINYL. REVISE
 MATERIAL ON WINDOWS INFORMATION AS REQUIRED. AS
 REQUIRED. SEE PLANS AND PRODUCT APPROVALS SUBMITTED.
  
 H)DOORS WITH GLAZING NEED TO BE CONSIDERED IN THE
 WINDOW AREA. REVISE AS REQUIRED. SEE SEC. R405.5.3.3
 FBC-ENERGY CONSERVATION.
  
 I) REVISE WINDOWS OVERHANG DEPTH AND SEPARATION TO
 MATCH PLANS.
  
 J)NEED TO PROVIDE HARD COPY OF ENERGY CALCULATIONS WITH
 ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471
 F. S. OR SUBMIT REPORT DIGITALLY SIGNED.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND
 SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS
 ARE NOT USING THE DEFAULT FACTOR.
  
  
 NOTE:
 VERIFY SIZE OF EGRESS WINDOW W11 WITH MANUFACTURER.
 36"X62" MAY NOT HAVE THE 24" CLEAR HEIGHT AND TOAL
 CLEAR OPENING OF 5.7. S.F. FOR SECOND FLOOR WINDOWS.
  
  
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  