Plan Review Notes
Plan Review Notes For Permit 18090121
Permit Number 18090121
Review Stop B
Sequence Number 3
Notes
Date Text
2019-03-22 08:12:48PROVISOS:
 1) FORMBOARD SURVEY TO INSPECTOR PRIOR TO POUR.
 2) PROVIDE PRODUCT APPROVALS FOR ROOFING WITH SUB
 PERMIT.
 3) PROVIDE PRODUCT APPROVALS FOR WINDOWS, DOORS,
 ROLL-UP DOOR AND STOREFRONT.
 4) AIPP
 5) ENGINEERED FLOODPROOFING SUBMITTAL PER FEMA TB 3-93
 FLOOD PROOFING AND CERT.
 THE DESIGN B.F.E IS 14.7 FEET NAVD88.-PENDING NFIP
 EVALUATION FOR SUBSTANTIAL IMPROVEMENT
  
 -PENDING NFIP EVALUATION FOR SUBSTANTIAL IMPROVEMENT
 1612.4.1 FBC[B] MODIFICATION OF ASCE 24. TABLE 6-1 AND
 SECTION 6.2.1 IN ASCE 24 SHALL BE MODIFIED AS FOLLOWS:
 1. THE TITLE OF TABLE 6.1 SHALL BE MINIMUM ELEVATION OF
 FLOODPROOFING, RELATIVE TO BASE FLOOD ELEVATION (BFE)
 OR DESIGN FLOOD ELEVATION (DFE), IN COASTAL A ZONES AND
 IN OTHER FLOOD HAZARD AREAS THAT ARE NOT HIGH RISK
 FLOOD HAZARD AREAS.
 2. SECTION 6.2.1 SHALL BE MODIFIED TO PERMIT DRY
 FLOODPROOFING IN COASTAL A ZONES, AS FOLLOWS: ?DRY
 FLOODPROOFING OF NONRESIDENTIAL STRUCTURES AND
 NONRESIDENTIAL AREAS OF MIXED-USE STRUCTURES SHALL NOT
 BE ALLOWED UNLESS SUCH STRUCTURES ARE LOCATED OUTSIDE
 OF HIGH RISK FLOOD HAZARD AREAS AND COASTAL HIGH HAZARD
 AREAS. DRY FLOODPROOFING SHALL BE PERMITTED IN COASTAL
 A ZONES PROVIDED WAVE LOADS AND THE POTENTIAL FOR
 EROSION AND LOCAL SCOUR ARE ACCOUNTED FOR IN THE
 DESIGN. DRY FLOODPROOFING OF RESIDENTIAL STRUCTURES OR
 RESIDENTIAL AREAS OF MIXED-USE STRUCTURES SHALL NOT BE
 PERMITTED.
  