2019-03-22 08:12:48 | PROVISOS: |
| 1) FORMBOARD SURVEY TO INSPECTOR PRIOR TO POUR. |
| 2) PROVIDE PRODUCT APPROVALS FOR ROOFING WITH SUB |
| PERMIT. |
| 3) PROVIDE PRODUCT APPROVALS FOR WINDOWS, DOORS, |
| ROLL-UP DOOR AND STOREFRONT. |
| 4) AIPP |
| 5) ENGINEERED FLOODPROOFING SUBMITTAL PER FEMA TB 3-93 |
| FLOOD PROOFING AND CERT. |
| THE DESIGN B.F.E IS 14.7 FEET NAVD88.-PENDING NFIP |
| EVALUATION FOR SUBSTANTIAL IMPROVEMENT |
| |
| -PENDING NFIP EVALUATION FOR SUBSTANTIAL IMPROVEMENT |
| 1612.4.1 FBC[B] MODIFICATION OF ASCE 24. TABLE 6-1 AND |
| SECTION 6.2.1 IN ASCE 24 SHALL BE MODIFIED AS FOLLOWS: |
| 1. THE TITLE OF TABLE 6.1 SHALL BE MINIMUM ELEVATION OF |
| FLOODPROOFING, RELATIVE TO BASE FLOOD ELEVATION (BFE) |
| OR DESIGN FLOOD ELEVATION (DFE), IN COASTAL A ZONES AND |
| IN OTHER FLOOD HAZARD AREAS THAT ARE NOT HIGH RISK |
| FLOOD HAZARD AREAS. |
| 2. SECTION 6.2.1 SHALL BE MODIFIED TO PERMIT DRY |
| FLOODPROOFING IN COASTAL A ZONES, AS FOLLOWS: ?DRY |
| FLOODPROOFING OF NONRESIDENTIAL STRUCTURES AND |
| NONRESIDENTIAL AREAS OF MIXED-USE STRUCTURES SHALL NOT |
| BE ALLOWED UNLESS SUCH STRUCTURES ARE LOCATED OUTSIDE |
| OF HIGH RISK FLOOD HAZARD AREAS AND COASTAL HIGH HAZARD |
| AREAS. DRY FLOODPROOFING SHALL BE PERMITTED IN COASTAL |
| A ZONES PROVIDED WAVE LOADS AND THE POTENTIAL FOR |
| EROSION AND LOCAL SCOUR ARE ACCOUNTED FOR IN THE |
| DESIGN. DRY FLOODPROOFING OF RESIDENTIAL STRUCTURES OR |
| RESIDENTIAL AREAS OF MIXED-USE STRUCTURES SHALL NOT BE |
| PERMITTED. |
| |