Date |
Text |
2018-09-12 17:00:34 | BUILDING PLAN REVIEW |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. SITE PLAN SP-1 WITH LATEST REVISION (9/6/18) LACKS |
| SIGNATURE AND SEALED OF DESIGN PROFESSIONAL. |
| 2. SITE PLAN SP-1 AND PAVING PLAN ARE INCONSISTENT. |
| 3. MILLING AND PAVING OF BISCAYNE DRIVE WILL REQUIRE A |
| RIGHT OF WAY ROW PERMIT. |
| 4. SITE PLAN SP-2 HAS MULTIPLE SITE IMPROVEMENTS NOT |
| RELEVANT TO THIS PAVING PERMIT. |
| 5. LANSCAPE PLANS LI-1, LP-1, LP-2 AND TD-1 ARE NOT |
| RELEVANT TO THIS PAVING PERMIT. |
| 6. THE ACCESSIBLE PARKING DETAIL ON PLAN PAGE SP-2 IS |
| OUT OF DATE. PLEASE SEE COPY OF CURRENT ACCESSIBLE |
| PARKING DETAIL FOR YOUR REVIEW AND USE. |
| 7. THE PARKING AREA SOUTH OF BISCAYNE DRIVE WHICH |
| SERVES THE NEW ADDITION REQUIRES AN ACCESSIBLE PARKING |
| SPACE. |
| 8. IDENTIFY THE ACCESSIBLE ROUTES FROM ACCESSIBLE |
| PARKING TO BUILDING ENTRANCES. |
| 9. REDUCE THE SUBMITTAL DOCUMENTS TO THE SITE PLAN WITH |
| THE MOST CURRENT REVISION AND THE PAVING, GRADING AND |
| DRAINAGE PLAN. |
| 10. HAVE DESIGN PROFESSIONALS SIGN AND SEAL THEIR |
| RESPECTIVE PLAN PAGES. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |