Date |
Text |
2018-10-31 10:52:40 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 18090013 |
| ADD: 440 COLUMBIA DR. SUITE:100 |
| CONT: FISHER CONTRACTING CORP. |
| TEL: 561-691-4716 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: WED. OCT. 31/2018 |
| ACTION: DENIED |
| |
| 1) PERMIT APPLICATION. UNDER THE HEADING OF ADDRESS AND |
| SUITE, THE SUITE INDICATES 110.THE PLANS INDICATE |
| SUITES 100A AND 100B IN THE RECEPTION AREAS. PLEASE |
| PROVIDE IF THE PERMIT IS FOR ONLY 1 SUITE OR 2 AND THE |
| SUITES NUMBERS. 107.2.1.3 ADDITIONAL INFORMATION IS |
| REQUIRED. |
| |
| 2) SHEET A4.1.2 (A100) AND SHEET A4.14 (B100) BOTH SHOW |
| A RECEPTION DESK WITH A DOUBLE TIER TOP. THE UPPER TOP |
| IS AT A HEIGHT OF 42 INCHES. WITH THIS BEING A BUSINESS |
| OCCUPANCY IT WOULD BE HARD TO DETERMINE IF PAYMENTS FOR |
| SERVICES RENDERED WOULD BE REQUIRED, WHERE EITHER |
| CHECKS AND OR CREDIT CARD TRANSACTIONS WOULD TAKE PLACE |
| AND COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE |
| SECTIONS 902.3 AND OR 904.4. |
| CHECK WRITING SURFACES. 2017 ACCESS. CODE 904.3.3 CHECK |
| WRITING SURFACES. |
| WHERE PROVIDED, CHECK WRITING SURFACES SHALL COMPLY |
| WITH 902.3. |
| 902.3HEIGHT. THE TOPS OF WORK SURFACES SHALL BE 28 |
| INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) MAXIMUM |
| ABOVE THE FINISH FLOOR OR GROUND. |
| 904.4 SERVICE COUNTERS. SALES COUNTERS AND SERVICE |
| COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2. THE |
| ACCESSIBLE PORTION OF THE COUNTER TOP SHALL EXTEND THE |
| SAME DEPTH AS THE SALES OR SERVICE COUNTER TOP. |
| THIS ADVISORY ONLY APPLIES TO EMPLOYEES!!! ADVISORY |
| 226.1. IN FACILITIES COVERED BY THE ADA, THIS |
| REQUIREMENT DOES NOT APPLY TO WORK SURFACES USED ONLY |
| BY EMPLOYEES. HOWEVER, THE ADA AND, WHERE APPLICABLE, |
| SECTION 504 OF THE REHABILITATION ACT OF 1973, AS |
| AMENDED, PROVIDE THAT EMPLOYEES ARE ENTITLED TO |
| ?REASONABLE ACCOMMODATIONS.? WITH RESPECT TO WORK |
| SURFACES, THIS MEANS THAT EMPLOYERS MAY NEED TO PROCURE |
| OR ADJUST WORK STATIONS SUCH AS DESKS, LABORATORY AND |
| WORK BENCHES, FUME HOODS, RECEPTION COUNTERS, TELLER |
| WINDOWS, STUDY CARRELS, COMMERCIAL KITCHEN COUNTERS, |
| AND CONFERENCE TABLES TO ACCOMMODATE THE INDIVIDUAL |
| NEEDS OF EMPLOYEES WITH DISABILITIES ON AN ?AS NEEDED? |
| BASIS. CONSIDER WORK SURFACES THAT ARE FLEXIBLE AND |
| PERMIT INSTALLATION AT VARIABLE HEIGHTS AND CLEARANCES. |
| |
| 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |