2018-10-22 08:57:01PER NFPA 101, CHAPTER 7 EXISTING OCCUPANCY
  
 37.1.2.2 SUBCLASSIFICATION OF OCCUPANCY.
 37.1.2.2.1 MERCANTILE OCCUPANCIES SHALL BE
 SUBCLASSIFIED AS
 FOLLOWS:
 (1) CLASS A, ALL MERCANTILE OCCUPANCIES HAVING AN
 AGGREGATE
 GROSS AREA OF MORE THAN 30,000 FT2 (2800 M) OR
 OCCUPYING
 MORE THAN THREE STORIES FOR SALES PURPOSES
  
 37.1.3 MULTIPLE OCCUPANCIES.
 37.1.3.1 GENERAL.
 37.1.3.1.1 ALL MULTIPLE OCCUPANCIES SHALL BE IN
 ACCORDANCE WITH
 6.1.14 AND 37.1.3.
 37.1.3.1.2 WHERE THERE ARE DIFFERENCES IN THE SPECIFIC
 REQUIREMENTS
 IN THIS CHAPTER AND PROVISIONS FOR MIXED OCCUPANCIES OR
 SEPARATED
 OCCUPANCIES AS SPECIFIED IN 6.1.14.3 AND 6.1.14.4, THE
 REQUIREMENTS OF THIS CHAPTER SHALL APPLY.
  
 37.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.
 37.3.4.1 GENERAL. CLASS A MERCANTILE OCCUPANCIES SHALL
 BE
 PROVIDED WITH A FIRE ALARM SYSTEM IN ACCORDANCE WITH
 SECTION 9.6.
  
 NFPA 101, CHAPTER 6, OCCUPANCY CLASSIFICATION
  
 6.1.14.2 DEFINITIONS.
 6.1.14.2.1 MULTIPLE OCCUPANCY. A BUILDING OR STRUCTURE
 IN WHICH TWO
 OR MORE CLASSES OF OCCUPANCY EXIST.
 6.1.14.2.2 MIXED OCCUPANCY. A MULTIPLE OCCUPANCY WHERE
 THE
 OCCUPANCIES ARE INTERMINGLED.
 6.1.14.2.3 SEPARATED OCCUPANCY. A MULTIPLE OCCUPANCY
 WHERE THE
 OCCUPANCIES ARE SEPARATED BY FIRE RESISTANCE.RATED
 ASSEMBLIES.
 6.1.14.3 MIXED OCCUPANCIES.
 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE
 CLASSIFIED AS TO ITS USE IN
 ACCORDANCE WITH SECTION 6.1.
 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST
 RESTRICTIVE
 REQUIREMENTS OF THE OCCUPANCIES INVOLVED, UNLESS
 SEPARATE SAFEGUARDS
 ARE APPROVED.
  
 6.1.14.4 SEPARATED OCCUPANCIES. (SEE ALSO 6.1.14.1.2.)
 6.1.14.4.1 WHERE SEPARATED OCCUPANCIES ARE PROVIDED,
 EACH PART OF THE
 BUILDING COMPRISING A DISTINCT OCCUPANCY, AS DESCRIBED
 IN THIS CHAPTER,
 SHALL BE COMPLETELY SEPARATED FROM OTHER OCCUPANCIES BY
 FIRE-RESISTIVE
 ASSEMBLIES, AS SPECIFIED IN 6.1.14.4.2, 6.1.14.4.3,
 TABLE 6.1.14.4.1(A),
 AND TABLE 6.1.14.4.1(B), UNLESS SEPARATION IS PROVIDED
 BY APPROVED
 EXISTING SEPARATIONS OR AS OTHERWISE PERMITTED BY
 6.1.14.4.6.
  
 SHOULD YOU CHOOSE TO BE A SEPARATED OCCUPANCY, YOUR
 OCCUPANCY SHALL BE THE SEPARATION REQUIRMENTS WHICH IS
 2 HOURS ACCORDING TO THE TABLE.
 PLEASE PROVIDE SPECIFIC DETAILS RELATING TO YOUR
 SPECIFIC WALLS THAT SEPARATE YOUR OCCUPANCY AND THOSE
 ON EACH SIDE.
  
  
 S. THOMAS
 561-804-4728