Plan Review Notes For Permit 18080725 |
Permit Number |
18080725 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2018-08-15 10:56:31 | RESIDENTIAL (R3) REROOF, BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- ADDRESS AND PROPERTY INFORMATION (REPORT DETAILS) | | SUBMITTED DON'T MATCH ADDRESS SHOWN ON THE PERMIT | | APPLICATION. REVISE AS REQUIRED. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 2- MULE-HIDE NOA 17-0824.11 SUBMITTED IS FOR MODIFIED | | ROOF SYSTEMS. THIS IS NOT AN UNDERLAYMENT FOR ROOF | | SHINGLES. PROVIDE PRODUCT APPROVAL (2 COPIES) FOR ROOF | | SHINGLES UNDERLAYMENT TO BE USED. FAC 61G20-3.001. | | | | 3- PERMIT APPLICATION SPECIFIES 3:12 ROOF PITCH. NEED | | TO SPECIFY TWO LAYERS OF UNDERLAYMENT AS REQUIRED BY | | SEC. R905.2.2 FBC-RESIDENTIAL. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION SEEMS | | TO BE LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS | | AND CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY | | SEC. 109.3 CITY AMENDMENTS. PROVIDE COPY OF CONTRACT | | SIGNED BY OWNER AND CONTRACTOR AND REVISE VALUATION AS | | REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|