Plan Review Notes
Plan Review Notes For Permit 18080466
Permit Number 18080466
Review Stop B
Sequence Number 1
Notes
Date Text
2018-09-26 14:52:14****CORRECTIONS****
 W.P.B. PERMIT: 18080466
 REVIEWED: SEPTEMBER 26, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. [FBC 107.2.5]PROVIDE SURVEY OF PROPERTY SHOWING
 EASEMENTS AND DISTANCE FROM PROPERTY LINES TO NEW
 STRUCTURE.
  
 2. [FBC R806.3]VENT AND INSULATION CLEARANCE.
 WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION
 SHALL NOT BLOCK THE FREE FLOW OF AIR. NOT LESS THAN A
 1-INCH (25 MM) SPACE SHALL BE PROVIDED BETWEEN THE
 INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION
 OF THE VENT.
 ADD NOTE TO STATE CLEARANCE AT SHEATHING TO BE 1?
 MINIMUM.
  
 3. [FBC AMENDED 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR
 WINDOWS, WINDOW MULL(IF APPLICABLE) AND DOORS, OR
 INDICATE THAT YOU WOULD LIKE THEM DEFERED.
  
 4. [FBC AMENDED 107.3.4.1]SUBMIT TRUSS SHOP DRAWINGS TO
 THE BUILDING INSPECTOR PRIOR TO INSTALLATION.
  
 5. [FBC AMENDED 107.2.1.2]ADDITIONAL INFO ON PRODUCT
 APPROVALS NEEDED FOR ROOFING, OR INDICATE THAT YOU
 WOULD TO DEFER IT UNTIL SUB-PERMIT APPLICATION.
 -SELECT WHICH SYSYTEM IS BEING USED BASED ON MDP.
 -PROVIDE ENGINEERING (RAS 117) FOR ENHANCED NAILING AS
 STATED IN PRODUCT APPROVAL UNDER GENERAL LIMITATIONS
 #7.
 -WHAT IS THE EXISTING ROOF PITCH, AND THE NEW ROOF TO
 BE SHINGLED?
 [FBC R905.2.2] [FBC R905.1.1]FOR ROOF SLOPES FROM TWO
 UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LESS
 THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12),
 DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  