2018-09-26 14:52:14 | ****CORRECTIONS**** |
| W.P.B. PERMIT: 18080466 |
| REVIEWED: SEPTEMBER 26, 2018 |
| |
| DYLAN BATTLES |
| BUILDING PLANS EXAMINER I |
| [email protected] |
| 561-805-6718 |
| |
| FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) |
| FBC B = FBC BUILDING |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC ENERGY = FBC ENERGY CONSERVATION |
| FBC R = FBC RESIDENTIAL |
| |
| 1. [FBC 107.2.5]PROVIDE SURVEY OF PROPERTY SHOWING |
| EASEMENTS AND DISTANCE FROM PROPERTY LINES TO NEW |
| STRUCTURE. |
| |
| 2. [FBC R806.3]VENT AND INSULATION CLEARANCE. |
| WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION |
| SHALL NOT BLOCK THE FREE FLOW OF AIR. NOT LESS THAN A |
| 1-INCH (25 MM) SPACE SHALL BE PROVIDED BETWEEN THE |
| INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION |
| OF THE VENT. |
| ADD NOTE TO STATE CLEARANCE AT SHEATHING TO BE 1? |
| MINIMUM. |
| |
| 3. [FBC AMENDED 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR |
| WINDOWS, WINDOW MULL(IF APPLICABLE) AND DOORS, OR |
| INDICATE THAT YOU WOULD LIKE THEM DEFERED. |
| |
| 4. [FBC AMENDED 107.3.4.1]SUBMIT TRUSS SHOP DRAWINGS TO |
| THE BUILDING INSPECTOR PRIOR TO INSTALLATION. |
| |
| 5. [FBC AMENDED 107.2.1.2]ADDITIONAL INFO ON PRODUCT |
| APPROVALS NEEDED FOR ROOFING, OR INDICATE THAT YOU |
| WOULD TO DEFER IT UNTIL SUB-PERMIT APPLICATION. |
| -SELECT WHICH SYSYTEM IS BEING USED BASED ON MDP. |
| -PROVIDE ENGINEERING (RAS 117) FOR ENHANCED NAILING AS |
| STATED IN PRODUCT APPROVAL UNDER GENERAL LIMITATIONS |
| #7. |
| -WHAT IS THE EXISTING ROOF PITCH, AND THE NEW ROOF TO |
| BE SHINGLED? |
| [FBC R905.2.2] [FBC R905.1.1]FOR ROOF SLOPES FROM TWO |
| UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LESS |
| THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), |
| DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED. |
| |
| NOTE: |
| -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| EACH COMMENT IS BEING ADDRESSED. |
| -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW |
| OF MATERIALS REQUESTED. |
| -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| NEED "VOID", RENDERING THEM NOT USABLE. |
| |