Notes
Date Text
2018-08-28 18:01:29****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1-2 OK
  
 3. SURVEY/SITE PLAN SHOWING COMPLIANCE WITH FBC B
 TABLES 705.8, 602.
  
 2ND REVIEW, GG102 WAS PROVIDED AND SHOWS 15'3" BETWEEN
 DREYFOOS BASEMENT AND PROPOSED PARKING GARAGE. THERE
 ARE ALSO NOTES REFERRING TO FOOTNOTE C AND G.
  
 ASSUMED PROPERTY LINE BETWEEN THE TWO BUILDINGS IS NOT
 CLEAR. PLEASE SEE FBC B CHAPTER 2, DEFINITION OF FIRE
 SEPARATION DISTANCE, ITEM 3. ASSUMED PROPERTY LINE
 BETWEEN THE EXISTING BUILDING AND PROPOSED BUILDING IS
 TO BE INDICATED. REVISE PLAN TO SHOW THE FOLLOWING:
  
 LOCATION OF ASSUMED PROPERTY LINE, DISTANCE TO DREYFOOS
 BASEMENT, DISTANCE TO PROPOSED GARAGE
 COMPLIANCE WITH FBC B TABLES 705.8, 602 FOR THE PARKING
 GARAGE TO THE ASSUMED PROPERTY LINE
 COMPLIANCE WITH FBC B TABLES 705.8, 602 FOR THE
 DREYFOOS BASEMENT
  
 ARCHITECT MAY SEND THIS PAGE TO ME VIA EMAIL FOR
 PRELIMINARY REVIEW.
  
 4-6. OK
  
 THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING PROVISOS
  
 A. PERMIT IS ISSUED AT RISK
 B. SHORING/RESHORE ENGINEERING IS TO BE SUBMITTED,
 REVIEWED AND ISSUED PRIOR TO INSTALLATION. FAILURE TO
 DO SO ***WILL*** RESULT IN A STOP WORK ORDER IF
 CONTRACTOR PROCEEDS WITHOUT SUBMITTAL OF
 SHORING/RESHORE ENGINEERING (#7, PAGE 4,
 THRESHOLD/SPECIAL INSPECTOR OBLIGATIONS IN THE
 AGREEMENT SIGNED BY ALL PARTIES).
  