Date |
Text |
2018-08-06 13:25:13 | FLORIDA BUILDING CODE 2017 6TH EDITION |
| FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED |
| NFPA 70 2014 EDITION |
| |
| JAKE LEAHY |
| ELECTRICAL PLANS EXAMINER II |
| 561-805-6713 |
| [email protected] |
| |
| MAIN DOES NOT SHOW SIZE IF IT IS 200A THEN WIRE TO |
| PANEL NEEDS TO BE 2/0 |
| |
| ALL NEW OUTLETS NEED TO BE WIRED PER 201.12(A), 210.8, |
| 210.52 |
| |
| ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH |
| CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT |
| KITCHENS, LAUNDRY ROOMS, FAMILY ROOMS, DINING ROOMS, |
| LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, |
| SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR |
| SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI PROTECTION. |
| NEC 210.12; FBC RE3902.16 |
| |
| E3902.9 LAUNDRY AREAS. 125-VOLT, SINGLE-PHASE, 15- AND |
| 20-AMPERE RECEPTACLES INSTALLED IN LAUNDRY |
| AREAS SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER |
| PROTECTION FOR PERSONNEL. [210.8(A)(9)] |
| |
| PROVIDE GFCI PROTECTION FOR ALL OUTLETS IN GARAGE. NEC |
| 210.8; FBC RE3902.2 |
| |
| PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A NOTE |
| WILL SUFFICE. NEC 406.12; FBC RE4002.14 |
| |
| E3901.2.2 WALL SPACE. |
| AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE |
| FOLLOWING: [210.52(A)(2)] |
| |
| 1. 1.ANY SPACE THAT IS 2 FEET (610 MM) OR MORE IN |
| WIDTH, INCLUDING SPACE MEASURED AROUND CORNERS, |
| AND THAT IS UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS |
| AND SIMILAR OPENINGS, FIREPLACES, AND FIXED CABINETS. |
| 2. 2.THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR |
| WALLS, EXCLUDING SLIDING PANELS. |
| 3. 3.THE SPACE CREATED BY FIXED ROOM DIVIDERS SUCH AS |
| RAILINGS AND FREESTANDING BAR-TYPE COUNTERS |
| |
| SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING |
| REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE |
| INSTALLED |
| SO THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR |
| LINE OF ANY WALL SPACE IS MORE THAN 6 FEET FROM A |
| RECEPTACLE |
| OUTLET. PROVIDE CORRECTION. NEC 210.52; FBC RE3901.2.1 |
| |
| OUTLET SPACING DOES NOT MEET CODE |