Plan Review Notes For Permit 18071450 |
Permit Number |
18071450 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2018-08-29 14:05:29 | PLUMBING PROVISO: | | 1. IN ORDER TO COMPLY WITH FBC ACC 202.4 GRAB BARS WILL | | BE INSTALLED IN BOTH EXISTING BATHROOMS THE GRAB BARS | | SHALL COMPLY WITH FBC ACC 604.5.1, 604.5.2 AND 609.4 | | 2. THE BREAK ROOM SINK SHALL COMPLY WITH FBC ACC 606.3 | | HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED WITH | | THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE | | 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | 606.2CLEAR FLOOR SPACE. 30? X 48? FOR PARALLEL | | APPROACH. | | | | | | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|