Plan Review Notes
Plan Review Notes For Permit 18070813
Permit Number 18070813
Review Stop B
Sequence Number 1
Notes
Date Text
2018-07-31 09:15:55PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE ENGINEER'S ROOF PRESSURE DRAWINGS ON SHEET S-1
 SHOWS THE SOLAR POOL HEATER PANELS LOCATED IN ROOF ZONE
 2 WITH AN UPLIFT PRESSURE OF -66.31 PSF. THE 4" LAG
 BOLTS WITH 3.5 INCHES OF THREAD HAVE A MAXIMUM PRESSURE
 OF 65 PSF. FBC-R301.2.1
  
 2) THE SIZE OF THE PANELS THAT WILL BE INSTALL HAS NOT
 BEEN PROVIDED. FBC-R107.2.1
  
 3) THE SPACING OF THE TOP HEADER ANCHORS IS NOT
 SPECIFIED. FBC-R 301.1
  
 4) THE ANCHORING OF THE BOTTOM HEADER AND THE
 SUPPLY/RETURN PIPING WAS NOT SPECIFIED. FBC-R301.1