2018-08-02 11:13:23FAILED
  
 1) THE SITE PLAN SHOWING THE PROPOSED LOCATION OF THE
 COVERED PARKING DOES NOT MATCH THE LOCATION APPROVED AS
 PART OF THE MINOR SITE PLAN AMENDMENT.
  
 2) THE LOCATION SHOWN ON THE SUBMITTED SITE PLAN DOES
 NOT INCLUDE A COVERED ADA SPACE. IF THIS NEW LOCATION
 IS WHERE THE COVERED PARKING IS NOW PROPOSED, THEN THE
 SITE PLAN NEEDS TO BE AMENDED TO PROVIDE A CODE
 COMPLIANT ADA SPACE, INCLUDING ACCESS AISLE AT THIS
 LOCATION. PLEASE NOTE THAT THE CONSTRUCTION SERVICES
 DIVISION WOULD NEED TO VERIFY THAT AN ADA SPACE AT THIS
 LOCATION MEETS ALL REQUIREMENTS.
  
 3) THE PROPOSED CANOPY STRUCTURE DOES NOT MATCH THE
 SIZE OF THE PARKING BAY SHOWN AND THE POSTS WOULD END
 UP BLOCKING SOME OF THE PARKING SPACES, MAKING THEM
 UNUSABLE.
  
 4) IF THE COVERED PARKING IS TO GO IN THE LOCATION THAT
 IT WAS APPROVED BY THE MINOR SITE PLAN AMENDMENT,
 PLEASE PROVIDE TWO COPIES OF THAT PLAN.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]