2018-07-23 11:30:43 | 1ST REVIEW: FBC 2017 6TH ED. RESIDENTIAL |
| 1ST REVIEW FBC 2017 EXISTING BUILDING |
| |
| 1 - FBC 107.2.1 - CONSTRUCTION DOCUMENTS SHALL BE OF |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| DETERMINED BY THE BUILDING OFFICIAL. |
| |
| PLEASE DECLARE UPON THE PLAN THE APPLICABLE CODE |
| CRITERIA GOVERNING THE PROPOSED WORK. PURSUANT TO |
| DISCUSSIONS WITH THE CONTRACTOR AND DESIGNER OF RECORD, |
| IT IS APPARENT THAT THE APPLICABLE CODE IS THE FBC 2017 |
| EXISTING BUILDING , MORE PARTICULARLY CHAPTER 13 |
| RELOCATED OR MOVED BUILDINGS. PLEASE PROVIDE A CLEAR |
| SCOPE OF WORK. THE SCOPE SHOULD IDENTIFY THAT AN |
| EXISTING STRUCTURE(S) IS BEING MOVED AND INCLUDE A |
| DESCRIPTION OF THE MEANS AND METHODS INTENDED TO |
| CONNECT A MOVED STRUCTURE TO THE FOUNDATION AND |
| STEMWALL. PROVIDE ADDITIONAL DETAILS OR NOTES RELATIVE |
| TO PROPOSED IMPROVEMENTS SUCH AS PLUMBING, ELECTRICAL, |
| HVAC, LANDSCAPING, DRIVEWAY, SEPARATE STRUCTURES, |
| INCLUDING A FUTURE POOL. THE ENTIRE SCOPE OF WORK TO |
| RESULT IN THE COMPLETE PROJECT SHOULD BE INCLUDED. YOU |
| MAY ELECT TO DEFER INFORMATION UNDER DESIGN WHICH IS |
| FORTHCOMING. PLEASE NOTE THAT EACH SEPARATE STRUCTURE |
| REQUIRES A SEPARATE PERMIT APPLICATION. ADDITIONALLY, |
| DRIVEWAYS, LANDSCAPING, POOLS, AND POOL BARRIERS |
| REQUIRES SEPARATE PERMIT SUBMITTALS. PLEASE NOTE OR |
| ACKNOWLEGE THIS ON THE PLAN. ADDITIONALLY THERE APPEARS |
| TO BE STREET IMPROVEMENTS PROPOSED. PLEASE ACKNOWLEGE |
| SUCH IMPROVEMENTS TO THE RIGHT OF WAY ARE TO BE |
| APPROVED BY THE CITY OF WEST PALM BEACH ENGINEERING |
| DEPARTMENT UNDER SEPARATE REVIEW. THE DRIVEWAY DEPICTED |
| ON THE PRELIMINARY SITE PLAN IS SHOWN TO CONNECT TO A |
| FUTURE ROAD EXTENTION. |
| |
| 2 - CHAPTER 481, FLORIDA STATUTES& 61G1 FLORIDA |
| ADMINISTRATIVE CODE. |
| |
| THE PLANS ARE DESIGNED BY MARK S MCCREE, REGISTERED |
| ARCITECT, BUT DO NOT BEAR A PHYSICAL SIGNATURE AND SEAL |
| AS REQUIRED. PLEASE PHYSICALLY SIGN AND SEAL THE |
| PHYSICAL SETS OF PLANS. |
| |
| 3A - FBC 107.2.5 SITE PLAN |
| |
| THE SITE PLAN MUST INCLUDE PROPOSED LOT DRAINAGE, AND |
| DESIGN FLOOD ELEVATIONS. |
| |
| 4 - FBC 107.3.5.3 PROVIDE THE FOLLOWING MINIMUM |
| SUBMITTAL DOCUMENTS: |
| A) CURRENT SURVEY. PLEASE NOTE THE SURVEY PROVIDED |
| APPEARS PENDING PLAT CONCEPT THAT IS NOT YET APPROVED. |
| B) DESIGN FLOOD ELEVATION, LOWEST FLOOR ELEVATION, |
| FLOOD DAMAGE RESISTANT MATERIALS. |
| C) PROPOSED ELEVATION CERTIFICATE FOR STRUCTURES AND |
| EQUIPMENT IN SPECIAL FLOOD HAZARD AREA. |
| |
| 5 - FBCE1302.6 FLOOD HAZARD AREAS. |
| |
| IF RELOCATED OR MOVED INTO A FLOOD HAZARD AREA, |
| STRUCTURES SHALL COMPLY WITH SECTION 1612 OF THE |
| FLORIDA BUILDING CODE, BUILDING, OR SECTION R322 OF THE |
| FLORIDA BUILDING CODE, RESIDENTIAL, AS APPLICABLE. |
| IT APPEARS FROM THE SUBMITTED SURVEY THAT THE STRUCTURE |
| IS PROPOSED TO BE LOCATED IN A FLOOD HAZARD AREA. SEE |
| ABOVE COMMENTS IN 4. |
| |