Date |
Text |
2018-10-03 12:24:32 | 10/03/18 READ E-MAIL FROM GERI SHUBERT. |
| |
| HAVE A GREAT DAY |
| GERI SHUBERT |
| DIVERSIFIED ROOFING SOLUTIONS, INC |
| 450 SOUTH OLD DIXIE HWY #1 |
| JUPITER, FL 33458 |
| 561-841-5676 |
| |
| |
| |
| |
| THIRD BUILDING REVIEW COMMENTS |
| CODE: FBC 6TH EDITION (2017). |
| |
| NOTE: |
| IT IS NOT CLEAR WHY SUBMITTING A TWO STORY WALL |
| SECTION. THE ITEMS BELOW ARE THE ONES THAT NEED TO BE |
| ADDRESSED. PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS, |
| SO WE CAN FINISH PROCESSING THIS PERMIT. NOTE: ROOF TO |
| WALL WORK NEED TO BE DONE UNDER A SUBPERMIT. ACCORDING |
| TO ROBERT (BROWN (BUILDING OFFICIAL) ROOFING CONTRACTOR |
| CAN NOT DO THIS WORK UNLESS LICENSE TO DO SO. |
| |
| |
| |
| PLAN REVIEW COMMENTS: |
| 1- IT LOOKS LIKE THE HOUSE WAS DESIGNED FOR SHINGLES AS |
| A ROOF COVERING. PROPOSED ROOFING MATERIAL IS CONCRETE |
| TILES. PROVIDE ENGINEERING ANALYSIS SHOWING THAT THE |
| EXISTING STRUCTURE IA CAPABLE OF SUPPORTING THE |
| ADDITIONAL LOAD. SEC. 107.2.1.2 CITY AMENDMENTS. |
| |
| RESPONSE: REPEAT COMMENT. NOT ADDRESSED. |
| |
| 2- HOUSE VALUE IS MORE THAN $300.000. NEED TO COMPLY |
| WITH THE ROOF TO WALL CONNECTIONS AS REQUIRED BY SEC. |
| 706.8 FBC-EXISTING-BUILDING. |
| RESPONSE: REPEAT COMMENT. NOT ADDRESSED. |
| |
| SEC. 706.8: |
| WHEN A ROOF COVERING ON AN EXISTING SITE-BUILT |
| SINGLE-FAMILY RESIDENTIAL STRUCTURE IS REMOVED AND |
| REPLACED ON A BUILDING THAT IS LOCATED IN THE |
| WIND-BORNE DEBRIS REGION AS DEFINED IN THE FLORIDA |
| BUILDING CODE, BUILDING AND THAT HAS AN INSURED VALUE |
| OF $300,000 OR MORE OR, IF THE BUILDING IS UNINSURED OR |
| FOR WHICH DOCUMENTATION OF INSURED VALUE IS NOT |
| PRESENTED, HAS A JUST VALUATION FOR THE STRUCTURE FOR |
| PURPOSES OF AD VALOREM TAXATION OF $300,000 OR MORE: |
| (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS |
| REQUIRED BY SECTION 706.8.1. |
| (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION |
| SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN |
| THE COST OF REROOFING. |
| EXCEPTION: SINGLE-FAMILY RESIDENTIAL STRUCTURES |
| PERMITTED SUBJECT TO THE FLORIDA BUILDING CODE ARE NOT |
| REQUIRED TO COMPLY WITH THIS SECTION. |
| |
| 3- NEW FLAT ROOF NOA 15-0622.21 AND ENGINEER RAS 117 |
| CALCULATIONS SUBMITTED ARE OK. NEED TO PROVIDE TWO |
| COPIES OF ENGINEER CALCULATIONS WITH ENGINEER'S |
| ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471 |
| WHEN ENGINEER IS SUBMITTING DOCUMENTS FOR PUBLIC |
| RECORDS. |
| |
| NEW COMMENTS: |
| 4- NEW ROOF TILE PRODUCT APPROVAL WAS SUBMITTED. ONLY |
| THE COVER PAGES OF FLORIDA PRODUCT APPROVAL FL7849-R11 |
| WAS SUBMITTED. NEED TO PROVIDE COMPLETE INSTALLATION |
| INSTRUCTIONS FOR SPECIFIC ROOF TILE TO BE INSTALLED. |
| AND CLEARLY SPECIFY/MARK ADHESIVE PADDY SIZE AND RIDGE |
| MATERIAL TO BE USED. PROVIDE 2 COPIES. |
| FAC 61G20-3.001. |
| |
| 5- NEW ROOF TILE ADHESIVE PRODUCT APPROVAL WAS |
| SUBMITTED. ONLY THE COVER PAGES OF FLORIDA PRODUCT |
| APPROVAL FL6332-R8 WAS SUBMITTED. NEED TO PROVIDE |
| COMPLETE INSTALLATION INSTRUCTIONS AND CLEARLY |
| SPECIFY/MARK ADHESIVE PADDY SIZE AND RIDGE MATERIAL ON |
| PAGES 3 AND 4 OF INSTALLATION INSTRUCTIONS. PROVIDE 2 |
| COPIES. |
| FAC 61G20-3.001. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |
| |