2018-06-27 17:45:341ST REVIEW FBC-2017 RESIDENTIAL MECHANICAL
 PERMIT #18060742
 6/27/18
  
 CODES IN EFFECT:
  
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE AC SYSTEM CHOSEN FOR THE GARAGE IS AN AHRI
 CERTIFIED HEAT PUMP SYSTEM. IT IS NOT CERTIFIIED,
 TESTED, OR RATED AS A DEHUMIDIFER. DEHUMIDIFIERS FALL
 UNDER A SEPARATE CERTIFICATION CATEGORY AND ARE NOT
 DESIGNED FOR COMFORT CONDITIONING. IF CHOOSING TO USE
 THIS SYSTEM, PLEASE PROVIDE AC LOAD CALCULATIONS PER
 SECTION R403.7.1 FBC EC, AND ENERGY CALCULATIONS FOR
 THE GARAGE PER THE FOLLOWING ENERGY CODE SECTIONS:
 R502.1, R503.2, R202 , AND R101.2- R101.5.1.2 FBC EC.
  
 2) PROVIDE AN ELECTRICAL PLAN- SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  