2018-10-11 08:08:11PLAN
 REVIEW COMMENTS
 2ND REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 1) THE ENTRY DOOR FOR THIS PROJECT IS A CUSTOM DOOR AND
 APPARENTLY DOES NOT HAVE A PRODUCT APPROVAL AS REQUIRED
 BY FAC RULE 61G20-3. THEREFORE, YOU ARE REQUIRED TO
 COMPLY WITH THE FOLLOWING.
 FBC-R612.2 PERFORMANCE.
 EXTERIOR WINDOWS AND DOORS SHALL BE DESIGNED TO RESIST
 THE DESIGN WIND LOADS SPECIFIED IN TABLE R301.2(2)
 ADJUSTED FOR HEIGHT AND EXPOSURE IN ACCORDANCE WITH
 TABLE FBC-R301.2(3). FOR TESTING REQUIRED IN SECTIONS
 R612.3 AND R612.5, DESIGN PRESSURES DETERMINED FROM
 TABLE R301.2(2) OR ASCE 7 ARE PERMITTED TO BE
 MULTIPLIED BY 0.6.
  
 FBC-R612.2.1 CUSTOM DOORS.
 CUSTOM (ONE-OF-A-KIND) EXTERIOR DOOR ASSEMBLIES SHALL
 BE TESTED BY AN APPROVED TESTING LABORATORY OR BE
 ENGINEERED IN ACCORDANCE WITH ACCEPTED ENGINEERING
 PRACTICES.
  
 FBC-R612.3.1 COMPARATIVE ANALYSIS.
 STRUCTURAL WIND LOAD DESIGN PRESSURES FOR WINDOW AND
 DOOR UNITS OTHER THAN THE SIZE TESTED IN ACCORDANCE
 WITH SECTION R612.3 SHALL BE PERMITTED TO BE DIFFERENT
 THAN THE DESIGN VALUE OF THE TESTED UNIT PROVIDED SUCH
 DIFFERENT PRESSURES ARE DETERMINED BY ACCEPTED
 ENGINEERING ANALYSIS OR VALIDATED BY AN ADDITIONAL TEST
 OF THE WINDOW OR DOOR UNIT TO THE DIFFERENT DESIGN
 PRESSURE IN ACCORDANCE WITH SECTION R612.3. ALL
 COMPONENTS OF THE ALTERNATIVE SIZE UNIT SHALL BE THE
 SAME AS THOSE OF THE TESTED OR LABELED UNIT.
  
  